Skip to content
Backyard pool with light steam rising off the water on a cool spring evening
Cost guide: pool heaters

Pool Heater Installation Cost: Gas Heater vs Heat Pump, Line by Line

Pool heater installation cost runs about $3,804 to $11,800 in 2026: the heater ($3,179 to $6,999 on the shelf), a gas line or 50 A circuit, an $82.60 to $500 permit and $500 to $1,500 of labor.

Free Pool Quote Match

Tell us about your pool project. We match you with licensed local pros who cover your area.

Step 1 of 3: Your project

Free for homeownersNo obligationAbout 60 seconds

  • ✓Line items with a Source columnShelf prices for nine heaters and heat pumps, gas line per foot, circuit, permit, labor and haul-away.
  • ✓Gas pipe size by distanceIFGC Table 402.4(2) checked against Hayward's and Pentair's tables: 1-1/4 in for 400,000 Btu/h up to 100 ft.
  • ✓Rules and rebates to 2031South Coast AQMD zero-NOx dates, DOE's 2028 standards, California Title 24 and a $350 to $800 utility rebate.
Quick answer
Swapping a gas pool heater on an existing line costs about $3,804 to $8,450, and $4,554 to $11,800 with a new 50 ft gas line and circuit, using 2026 shelf prices and Angi’s labor and permit ranges. A heat pump with a new 45 to 50 A circuit runs $5,675 to $10,649. Angi’s US average is $3,038.
$3,804 to $8,450
Gas heater, swap on existing line
$5,675 to $10,649
Heat pump, new circuit
$3,038
US average, all types

Key takeaways

  • 2026 shelf prices run $3,179 to $6,399.99 for 250,000 to 400,000 Btu/h gas pool heaters and $4,800 to $6,999 for 138,000 to 140,000 Btu/h heat pumps (Leslie's and Walmart.com listings in our pool equipment price index).
  • A gas line to a pool heater costs about $20 per linear foot, within $15 to $25, and a 400,000 Btu/h heater needs 1-1/4 in Schedule 40 pipe up to 100 ft from the meter (Angi; IFGC Table 402.4(2); Hayward Table 10).
  • Heat pumps need a 208 to 230 V circuit: Hayward’s HP31005T lists a 42 A minimum circuit ampacity and a 45 A breaker, while a Pentair MasterTemp gas heater draws about 5 A at 120 V on a 15 A circuit (Hayward manual; Pentair manual).
  • Heater permits run $82.60 per pool heater in Miami-Dade County from Oct 1, 2026 and $150 for a new heater with lines in Palm Beach County (Miami-Dade IO 4-63; Palm Beach County fees).
  • Gas pool heaters sold or installed in the South Coast AQMD must be zero-NOx from Jan 1, 2028 in new buildings and Jan 1, 2031 in existing ones (Rule 1146.2).

How much does it cost to install a pool heater?

Expect $3,804 to $8,450 to swap a gas heater on an existing line and $5,425 to $8,549 to swap a heat pump on an existing circuit, from 2026 shelf prices plus Angi’s labor and permit ranges. New gas lines or circuits push the top to $11,800. Angi’s US average of $3,038 sits below most of these builds because its unit ranges predate 2026 shelf prices.

$3,038
Average pool heater installation, US (Angi, updated Mar 17, 2026)
Source: Angi
$3,179 to $6,999
2026 shelf price, 250k to 400k gas and 138k to 140k heat pumps
$20 per ft
Gas line to a pool heater, typical (range $15 to $25)
Source: Angi
45 to 50 A
Recommended breaker for 100,000 to 140,000 Btu/h heat pumps
Key numbers for pool heater installation cost, US, 2025 to 2026, with source and date
NumberValueSource and date
Average pool heater installation, US$3,038; normal range $1,830 to $4,249Angi, updated Mar 17, 2026
Gas heater shelf price, 250,000 to 400,000 Btu/h$3,179 to $6,399.99Leslie's and Walmart.com listings, Jun to Oct 2026
Heat pump shelf price, 138,000 to 140,000 Btu/h$4,800 to $6,999Leslie's and Walmart.com listings, May to Oct 2026
Gas line labor and pipe for a pool heater$15 to $25 per ft; about $20 per ftAngi gas line guide, Mar 17, 2026
Gas pipe for a 400,000 Btu/h heater, 50 to 100 ft from the meter1-1/4 in Schedule 40IFGC Table 402.4(2); Hayward Table 10
Heat pump circuit208 to 230 V; 33 to 43 A minimum circuit ampacity; 40 to 50 A recommended breakerPentair UltraTemp guide; Hayward HeatPro manual
Heater permit line items$82.60 (Miami-Dade); $150 new with lines (Palm Beach County)County fee schedules, 2026
Federal gas pool heater minimum82% thermal efficiency until May 30, 202810 CFR 430.32(k)

Sources: Angi pool heater guide (archived Apr 18, 2026); PC&S pool equipment price index; Angi gas line guide; IFGC Table 402.4(2); Pentair UltraTemp guide; Hayward HeatPro manual; Miami-Dade IO 4-63; Palm Beach County; 10 CFR 430.32(k). Download CSV

Pool heater installed cost: PC&S line-item build vs published averagesLow to high, US dollars, 2025 to 2026 sources
Pool heater installed cost: PC&S line-item build vs published averagesRange chart: gas heater with a new 50 ft line $4,554 to $11,800; gas swap $3,804 to $8,450; heat pump with new circuit $5,675 to $10,649; heat pump swap $5,425 to $8,549; Angi gas $1,500 to $6,000; Angi heat pump $2,500 to $7,500; Homewyse 150,000 Btu/h replacement $2,760 to $4,530.$0$3,000$6,000$9,000$12,000Gas, new 50 ft line and circuit (PC&S line items): $4,554 to $11,800Gas, new 50 ft line and circuit (PC&S line items)Gas, swap on existing line (PC&S): $3,804 to $8,450Gas, swap on existing line (PC&S)Heat pump, new 50 A circuit (PC&S): $5,675 to $10,649Heat pump, new 50 A circuit (PC&S)Heat pump, swap on existing circuit (PC&S): $5,425 to $8,549Heat pump, swap on existing circuit (PC&S)Angi: gas or propane, installed: $1,500 to $6,000Angi: gas or propane, installedAngi: heat pump, installed: $2,500 to $7,500Angi: heat pump, installedHomewyse: replace a 150,000 Btu/h gas heater: $2,760 to $4,530Homewyse: replace a 150,000 Btu/h gas heater

Our ranges run higher than the cost guides mostly because 2026 shelf prices for 250,000 to 400,000 Btu/h gas heaters and 140,000 Btu/h heat pumps start above the guides' unit ranges.

Source: PC&S line items from Leslie's and Walmart.com listings (2026), Angi gas line and electrical ranges (Mar 2026), Angi pool heater guide (Mar 2026), Homewyse (May 2026). Download chart data (CSV)

The gap with the cost guides is mostly the box. Angi puts the gas heater itself at $1,000 to $4,500 and a heat pump at $2,000 to $6,500 (Angi), while the cheapest 250,000 Btu/h class gas heater in our 2026 captures was $3,179 and the 140,000 Btu/h heat pumps were $4,800 to $6,999. The BLS producer price index for heating equipment rose 12.0% from January 2024 to August 2026, as our pool equipment price index tracks. Homewyse’s May 2026 estimate for replacing a 150,000 Btu/h gas heater, $2,760 to $4,530, fits a smaller unit (Homewyse).

Pool heater installation cost line by line: gas heater vs heat pump

A gas heater with a new 50 ft gas line totals $4,554 to $11,800 and a heat pump with a new 208 to 230 V circuit $5,675 to $10,649. The heater is 54% to 85% of each total. A gas line adds $750 to $1,250 for 50 ft at $15 to $25 a foot; a new heat pump circuit adds $250 to $2,100.

Line-item installed cost: gas heater with a new 50 ft gas line vs heat pump with a new circuit, low and high, US, 2026
Line itemGas heater, new gas line: lowGas heater: highHeat pump, new circuit: lowHeat pump: highSource
Heater or heat pump (2026 shelf price)$3,179$6,399.99$4,800$6,999Leslie's and Walmart.com listings, May to Oct 2026 (266k to 400k gas; 138k to 140k heat pump)
Gas line, 50 ft at $15 to $25 per ft (1-1/4 in for 400,000 Btu/h)$750$1,250n/an/aAngi gas line guide (Mar 2026); pipe size from IFGC Table 402.4(2) and Hayward Table 10
Electrical circuit (gas: 15 A at the pad; heat pump: 208-230 V, 45 to 50 A)$0$2,100$250$2,100Angi electrical circuits $250 to $2,100; $0 low case assumes an existing pad circuit for the gas heater; MCA from Hayward and Pentair manuals
Permit$100$500$100$500Angi; Miami-Dade $82.60 heater plus $9.91 gas outlet; Palm Beach County $150 new heater with lines
Installation labor$500$1,500$500$1,000Angi, Mar 17, 2026
Old heater removal$25$50$25$50Angi; HomeAdvisor
Total installed (rounded to the dollar)$4,554$11,800$5,675$10,649PC&S sum of the lines above
Utility rebate where offered (heat pump)n/an/a$350 to $800 back$350 to $800 backCenterPoint Energy Indiana 2026: $350 at COP 5.5 to 5.9, $800 at COP 6.0 or more

Sources: Leslie's, Leslie's MasterTemp listing, Leslie's Crosswind listing and Walmart.com via the PC&S price index; Angi gas line guide; Angi pool heater guide; HomeAdvisor; IFGC Table 402.4(2); Hayward Table 10; Hayward and Pentair electrical specs; Miami-Dade; Palm Beach County; CenterPoint Energy Indiana. Totals are PC&S sums. Download CSV

The low gas case assumes a 15 A circuit already reaches the pad; Pentair’s MasterTemp draws about 5 A at 120 V and asks for a 15 A circuit. The high cases include a new circuit at Angi’s top figure of $2,100. Neither total includes a new concrete pad, a new gas meter, which Angi puts at $300 to $600 installed, or trenching under hardscape.

Size changes the line items too. A 250,000 Btu/h heater can run on 1 in pipe for 50 ft, while a 400,000 Btu/h heater needs 1-1/4 in, and every step up in pipe adds material and labor. How much heater your pool needs is worked out in our guide to what size pool heater you need.

How much does a gas pool heater cost in 2026?

A gas pool heater cost $3,179 to $6,399.99 on the shelf in 2026 for 250,000 to 400,000 Btu/h natural gas models at Leslie’s and Walmart.com. Five 400,000 Btu/h class listings had a median of $4,200. Installed on an existing gas line, that becomes about $3,804 to $8,450 with labor, permit and removal.

2026 shelf prices of six pool heaters and heat pumpsRegular price at Leslie's or Walmart.com, captured May to Oct 2026
2026 shelf prices of six pool heaters and heat pumpsBar chart: Hayward HeatPro 140k heat pump $6,999, Pentair MasterTemp 400 gas $6,399.99, Raypak Crosswind V 8550 heat pump $4,800, Hayward W3HS250FDN gas $4,299, Raypak 009219 gas 399k $4,200, Raypak 009217 gas 266k $3,179.Hayward HeatPro 140k heat pump: $6,999Hayward HeatPro 140k heat pump$6,999Pentair MasterTemp 400 gas: $6,400Pentair MasterTemp 400 gas$6,400Raypak Crosswind V 8550 heat pump, 138k: $4,800Raypak Crosswind V 8550 heat pump, 138k$4,800Hayward W3HS250FDN gas, 250k: $4,299Hayward W3HS250FDN gas, 250k$4,299Raypak 009219 gas, 399k: $4,200Raypak 009219 gas, 399k$4,200Raypak 009217 gas, 266k: $3,179Raypak 009217 gas, 266k$3,179

Heat pump bars are highlighted. Shelf prices exclude shipping, tax and installation.

Source: Leslie's product pages (Wayback captures) and Walmart.com listings via PC&S pool equipment price index. Download chart data (CSV)

2026 shelf prices for nine pool heaters and heat pumps, with retailer and capture date
Heater (model as listed)TypeRated sizeRetailerRegular priceCapture date
Raypak 009217 Digital, natural gasGas266,000 Btu/h inputLeslie's (Wayback capture)$3,1792026-06-06
Hayward W3HS250FDN Universal H-Series Low NOx with OmniXGas250,000 Btu/h inputLeslie's (Wayback capture)$4,2992026-06-30
Raypak 009219 Digital, natural gasGas399,000 Btu/h inputLeslie's (Wayback capture)$4,2002026-06-06
Raypak AVIA P-R404A-EN-C, natural gasGas400,000 Btu/h classLeslie's (Wayback capture)$4,2002026-06-30
Raypak 406,000 Btu natural gas heater (RAY-009219 listing)Gas406,000 Btu/h as listedWalmart.com (seller WaterThat)$4,2002026-10-14
Pentair MasterTemp 460775 Low NOx ASME, natural gasGas400,000 Btu/h inputLeslie's (Wayback capture)$6,399.992026-09-16
Raypak Crosswind V 8550Heat pump138,000 Btu/hLeslie's (Wayback capture)$4,8002026-06-30
Hayward HeatPro MCHX, heat onlyHeat pump140,000 Btu/hLeslie's (Wayback capture)$6,9992026-05-27
Hayward W3HP21404T HeatProHeat pump140,000 Btu/hWalmart.com (seller Dohenys)$6,9992026-10-14

Sources: Leslie's product pages via Wayback Machine captures (e.g. Raypak 009219, Pentair MasterTemp 460775, Raypak Crosswind V 8550) and Walmart.com, compiled in the PC&S pool equipment price index. Download CSV

Pool heater cost claims in top-ranking guides checked against primary sources and arithmetic
Claim in a top-ranking guideWhat the primary source or arithmetic showsSources
Angi gas line guide summary: gas line installation costs $260 to $820 per linear footThe same guide prices gas line at $15 to $25 per linear foot, about $20 per foot for a pool heater, and $350 to $2,100 in total for a pool heater lineAngi gas line guide (Mar 17, 2026)
HomeAdvisor: electrical circuits $250 to $2,100 to $1,900Angi lists electrical circuits at $250 to $2,100 and water lines at $350 to $1,900; the HomeAdvisor line merges two rangesHomeAdvisor (Apr 30, 2025); Angi (Mar 17, 2026)
Angi and HomeAdvisor: a 20,000 gallon pool needs an 80,000 to 120,000 Btu gas heaterA 20 F rise in 24 hours takes 139,000 Btu/h of output, a 165,476 Btu/h input at 84% (gallons x 8.34 x rise / hours)Angi; HomeAdvisor; Pentair Engineering Data; PC&S sizing guide
Angi: the gas heater itself costs $1,000 to $4,5002026 shelf prices for 250,000 to 400,000 Btu/h gas heaters run $3,179 to $6,399.99Angi; Leslie's and Walmart.com listings
Angi: the heat pump itself costs $2,000 to $6,5002026 shelf prices for 138,000 to 140,000 Btu/h heat pumps run $4,800 to $6,999Angi; Leslie's and Walmart.com listings

Sources: Angi gas line guide; Angi pool heater guide; HomeAdvisor; PC&S price index; PC&S sizing guide (Pentair formula). Download CSV

Low-NOx and ASME-rated versions cost more: Pentair’s 400,000 Btu/h MasterTemp Low NOx ASME listed at $6,399.99 in September 2026 against $4,200 for Raypak’s 399,000 Btu/h digital heater in June. Federal rules set the floor at 82% thermal efficiency for gas pool heaters made before May 30, 2028 (10 CFR 430.32(k)). Running cost is a separate bill: our cost to heat a pool study prices delivered gas heat at $31.14 per MMBtu at July 2026 US prices.

What does a gas line to a pool heater cost, and what size pipe?

Budget about $20 a foot, within $15 to $25, so a 50 ft run costs $750 to $1,250. Pipe size follows the heater’s input and the distance from the meter: under IFGC Table 402.4(2), a 400,000 Btu/h heater needs 1-1/4 in Schedule 40 pipe from 30 to 100 ft and 1-1/2 in at 200 ft. Hayward’s and Pentair’s manuals agree.

Minimum gas pipe size by heater input and run length: IFGC Table 402.4(2) vs Hayward's Table 10
Heater input (Btu/h)Gas flow at 1,000 Btu per cu ft (cfh)IFGC 402.4(2): 30 ft runIFGC: 50 ftIFGC: 100 ftIFGC: 200 ftHayward Table 10: 0 to 50 ft / 50 to 100 / 100 to 200 / 200 to 300 ft
150,0001503/4 in3/4 in1 in1-1/4 in3/4 in / 1 in / 1-1/4 in / 1-1/4 in (H150FDN)
250,0002501 in1 in1-1/4 in1-1/4 in1 in / 1-1/4 in / 1-1/4 in / 1-1/2 in (H250FDN)
300,0003001 in1-1/4 in1-1/4 in1-1/2 in1-1/4 in / 1-1/4 in / 1-1/2 in / 2 in (H300FDN)
400,0004001-1/4 in1-1/4 in1-1/4 in1-1/2 in1-1/4 in / 1-1/4 in / 1-1/2 in / 2 in (H400FDN)

Sources: 2021 International Fuel Gas Code Table 402.4(2), as adopted in the 2021 Seattle Fuel Gas Code (Schedule 40 metallic pipe, natural gas, under 2 psi, 0.5 in w.c. drop, specific gravity 0.60); Hayward Universal H-Series manual, Table 10; cubic feet at 1,000 Btu per cu ft (Pentair MasterTemp guide); PC&S lookup rounding each run up to the next tabulated length. Download CSV

How far each gas pipe size can carry a pool heater's gasIFGC Table 402.4(2): Schedule 40 steel, natural gas under 2 psi, 0.5 in w.c. drop, cubic feet per hour
How far each gas pipe size can carry a pool heater's gasLine chart: capacity falls with length; 1-1/4 in pipe carries 957 cfh at 20 ft and 400 cfh at 100 ft, exactly a 400,000 Btu/h heater; 1 in pipe drops below 400 cfh beyond 20 ft and below 250 cfh beyond 60 ft.06251,2501,8752,500102030405060801001251502003/4 in pipe (cfh), 10: 3603/4 in pipe (cfh), 20: 2473/4 in pipe (cfh), 30: 1993/4 in pipe (cfh), 40: 1703/4 in pipe (cfh), 50: 1513/4 in pipe (cfh), 60: 1373/4 in pipe (cfh), 80: 1173/4 in pipe (cfh), 100: 1043/4 in pipe (cfh), 125: 923/4 in pipe (cfh), 150: 833/4 in pipe (cfh), 200: 713/4 in pipe (cfh)1 in pipe (cfh), 10: 6781 in pipe (cfh), 20: 4661 in pipe (cfh), 30: 3741 in pipe (cfh), 40: 3201 in pipe (cfh), 50: 2841 in pipe (cfh), 60: 2571 in pipe (cfh), 80: 2201 in pipe (cfh), 100: 1951 in pipe (cfh), 125: 1731 in pipe (cfh), 150: 1571 in pipe (cfh), 200: 1341 in pipe (cfh)1-1/4 in pipe (cfh), 10: 1,3901-1/4 in pipe (cfh), 20: 9571-1/4 in pipe (cfh), 30: 7681-1/4 in pipe (cfh), 40: 6571-1/4 in pipe (cfh), 50: 5831-1/4 in pipe (cfh), 60: 5281-1/4 in pipe (cfh), 80: 4521-1/4 in pipe (cfh), 100: 4001-1/4 in pipe (cfh), 125: 3551-1/4 in pipe (cfh), 150: 3221-1/4 in pipe (cfh), 200: 2751-1/4 in pipe (cfh)1-1/2 in pipe (cfh), 10: 2,0901-1/2 in pipe (cfh), 20: 1,4301-1/2 in pipe (cfh), 30: 1,1501-1/2 in pipe (cfh), 40: 9851-1/2 in pipe (cfh), 50: 8731-1/2 in pipe (cfh), 60: 7911-1/2 in pipe (cfh), 80: 6771-1/2 in pipe (cfh), 100: 6001-1/2 in pipe (cfh), 125: 5321-1/2 in pipe (cfh), 150: 4821-1/2 in pipe (cfh), 200: 4121-1/2 in pipe (cfh)400,000 Btu/h heater needs (cfh), 10: 400400,000 Btu/h heater needs (cfh), 20: 400400,000 Btu/h heater needs (cfh), 30: 400400,000 Btu/h heater needs (cfh), 40: 400400,000 Btu/h heater needs (cfh), 50: 400400,000 Btu/h heater needs (cfh), 60: 400400,000 Btu/h heater needs (cfh), 80: 400400,000 Btu/h heater needs (cfh), 100: 400400,000 Btu/h heater needs (cfh), 125: 400400,000 Btu/h heater needs (cfh), 150: 400400,000 Btu/h heater needs (cfh), 200: 400400,000 Btu/h heater needs (cfh)250,000 Btu/h heater needs (cfh), 10: 250250,000 Btu/h heater needs (cfh), 20: 250250,000 Btu/h heater needs (cfh), 30: 250250,000 Btu/h heater needs (cfh), 40: 250250,000 Btu/h heater needs (cfh), 50: 250250,000 Btu/h heater needs (cfh), 60: 250250,000 Btu/h heater needs (cfh), 80: 250250,000 Btu/h heater needs (cfh), 100: 250250,000 Btu/h heater needs (cfh), 125: 250250,000 Btu/h heater needs (cfh), 150: 250250,000 Btu/h heater needs (cfh), 200: 250250,000 Btu/h heater needs (cfh)

Size for every appliance on the line, not the heater alone (IFGC 402.2).

Source: 2021 International Fuel Gas Code Table 402.4(2) as adopted in the 2021 Seattle Fuel Gas Code; heater demand at 1,000 Btu per cubic foot (Pentair MasterTemp guide). Download chart data (CSV)

Hayward's Table 10 for Universal H-Series natural gas heaters: 1-1/4 in pipe for a 400,000 Btu/h H400FDN up to 100 ft from the meter and 1-1/2 in to 200 ft, at a 0.5 in w.c. drop. Accessed Oct 27, 2026.
Hayward’s Table 10 for Universal H-Series natural gas heaters: 1-1/4 in pipe for a 400,000 Btu/h H400FDN up to 100 ft from the meter and 1-1/2 in to 200 ft, at a 0.5 in w.c. drop. Accessed Oct 27, 2026.

Pentair’s MasterTemp table lands in the same place: a 400 model on natural gas can run 20 ft on 1 in pipe, 100 ft on 1-1/4 in and 200 ft on 1-1/2 in, counting 3 extra feet for every elbow (Pentair MasterTemp guide, Table 2). The same guide asks for 4 to 14 in w.c. of gas pressure at the heater and lets propane pipe run 1/4 in smaller, with a 1/2 in minimum. Angi puts the full gas line for a pool heater at $350 to $2,100 (Angi).

How much does a pool heat pump cost to install?

A pool heat pump costs $4,800 to $6,999 on the shelf for 138,000 to 140,000 Btu/h models in 2026, and $5,425 to $10,649 installed. The extra cost over gas is electrical: these units need a 208 to 230 V circuit with a 33 to 43 A minimum circuit ampacity and a 40 to 50 A recommended breaker, plus a disconnect within sight. Output at 50 F air and monthly running cost against gas in five cities, model by model, are in our heat pump pool heater guide.

Pool heat pump electrical requirements by model, with a gas heater for contrast
ModelVoltageMinimum circuit ampacity (A)Recommended breaker or fuse (A)Maximum breaker or fuse (A)Source
Hayward HeatPro HP31005T (100,000 Btu/h at 80 F air)208-230 V, 1 phase424570Hayward HeatPro manual 51300056501 Rev G
Pentair UltraTemp 70208-230 V, 1 phase334050Pentair UltraTemp installation guide
Pentair UltraTemp 90208-230 V, 1 phase405060Pentair UltraTemp installation guide
Pentair UltraTemp 110 and 120208-230 V, 1 phase425070Pentair UltraTemp installation guide
Pentair UltraTemp 140208-230 V, 1 phase435070Pentair UltraTemp installation guide
Pentair MasterTemp gas heater (for contrast)120 or 240 Vabout 5 A draw at 120 V, 2.5 A at 240 V15 A circuit, 14 gauge wiren/aPentair MasterTemp installation guide

Sources: Hayward HeatPro manual 51300056501 Rev G (HP31005T); Pentair UltraTemp installation and user's guide, Electrical Supply table; Pentair MasterTemp guide, electrical connections. Download CSV

Hayward tells the electrician to size the wire from the unit’s minimum circuit ampacity under the National Electrical Code, to fit a disconnect within line of sight of the heat pump, and to run a No. 8 AWG solid copper bonding wire to the pool’s bonding grid (Hayward manual). Placement matters for cost too: Hayward calls for 24 in of clearance on all sides and at least 60 in from the inside wall of the pool, so a crowded pad can mean a new pad. Bonding is covered in our pool bonding guide.

Rebates can trim the box price. CenterPoint Energy in Indiana pays $350 for heat pump pool heaters rated COP 5.5 to 5.9 and $800 for COP 6.0 or more, for units bought and installed in 2026, with the claim due within 60 days (CenterPoint 2026 application). Pentair offers up to $200 back on select UltraTemp models through Dec 31, 2026 (Pentair rebate center). The heat pump’s running cost, $10.73 per MMBtu of heat at July 2026 prices and a COP of 5.0, is priced by state in our cost to heat a pool study.

Do you need a permit to install a pool heater, and what does labor cost?

Usually yes, and often more than one: the heater, the gas line and the electrical circuit can each be a separate permit line. Miami-Dade County charges $82.60 per pool heater plus $9.91 per gas outlet, and Palm Beach County $150 for a new heater with lines. Angi puts installation labor at $500 to $1,500 for gas and $500 to $1,000 for heat pumps.

Pool heater permit fees from two county fee schedules and the national cost-guide range
JurisdictionFee itemFeeScheduleSource
Miami-Dade County (unincorporated), FLPlumbing: swimming pool heater, each$82.60Implementing Order 4-63, effective Oct 1, 2026Miami-Dade IO 4-63
Miami-Dade County (unincorporated), FLNatural gas or LP: each outlet, single family (includes meters and regulators)$9.91IO 4-63, effective Oct 1, 2026Miami-Dade IO 4-63
Palm Beach County, FLPool or spa heater, new with lines$150PZB fee list printed Mar 2, 2026Palm Beach County PZB Fees
Palm Beach County, FLPool or spa heater replacement, 1 and 2 family$100PZB fee list printed Mar 2, 2026Palm Beach County PZB Fees
Palm Beach County, FLGas lines only$100PZB fee list printed Mar 2, 2026Palm Beach County PZB Fees
National range (cost guides)Permits for a pool heater installation$100 to $500Angi, updated Mar 17, 2026Angi

Sources: Miami-Dade County Implementing Order 4-63 (effective Oct 1, 2026); Palm Beach County PZB fee list (printed Mar 2, 2026); Angi. Surcharges and plan review can apply on top; ask the permit office for the all-in figure. Download CSV

Pool heater installation labor: cost-guide ranges and trade wages
Trade or taskFigureWhat it isSource and date
Pool heater installation labor, gas$500 to $1,500Cost guide range, billedAngi, Mar 17, 2026
Pool heat pump installation labor$500 to $1,000Cost guide range, billedAngi, Mar 17, 2026
Plumber, billed hourly$45 to $200 an hourCost guide rangeAngi, Mar 17, 2026
Electrician, billed hourly$50 to $100 an hourCost guide rangeAngi, Mar 17, 2026
Plumbers, pipefitters and steamfitters, median wage$30.67 an hour (mean $34.70)What the worker earns, not the billed rateBLS OEWS, May 2025
Electricians, median wage$30.38 an hour (mean $34.37)What the worker earns, not the billed rateBLS OEWS, May 2025
Old heater removal and disposal$25 to $50Cost guide rangeAngi, Mar 17, 2026; HomeAdvisor, Apr 30, 2025

Sources: Angi (Mar 17, 2026); HomeAdvisor (Apr 30, 2025); BLS Occupational Employment and Wage Statistics, May 2025, series OEUN000000000000047215208 and OEUN000000000000047211108. Download CSV

  1. Size the heater and pick the fuelArea x temperature rise x 12 gives Btu/h of output (DOE); check local rules before choosing gas.
  2. Pull the permitsHeater, gas and electrical lines as your county lists them, for example $82.60 plus $9.91 per gas outlet in Miami-Dade.
  3. Set the pad and clearancesHeat pumps: 24 in on all sides and at least 60 in from the pool wall (Hayward).
  4. Run gas or powerGas: pipe sized for the full connected load, a manual shutoff and sediment trap outside the cabinet (Pentair). Heat pump: 208 to 230 V circuit at the listed breaker size, disconnect within sight.
  5. Plumb after the filterPlace any chlorinator downstream of the heater with a check valve between them (Pentair; Hayward); in California, Title 24 asks for 18 in of pipe between filter and heater.
  6. Bond, test and inspectNo. 8 AWG solid copper bond, gas leak test with soapy water, gas pressure 4 to 14 in w.c. at the heater, then the final inspection.

Trade wages explain only part of the billed rate. BLS puts the May 2025 median wage at $30.67 an hour for plumbers and $30.38 for electricians (BLS), against Angi’s billed $45 to $200 and $50 to $100, which carry overhead, insurance and travel. Permit steps for a whole pool are in our pool permit guide.

Which rules change pool heater installation by 2028 and 2031?

Three dated rules matter. California permits applied for since Jan 1, 2026 need a heat pump or solar as the primary pool heat. The South Coast AQMD requires zero-NOx pool heaters from Jan 1, 2028 in new buildings and Jan 1, 2031 in existing ones. DOE’s standards from May 30, 2028 tighten gas efficiency and set an electric level that resistance heaters do not reach.

Pool heater rules and rebate dates, 2013 to 2031
  1. FederalFederal 82% floor for gas pool heatersGas-fired pool heaters made from this date to May 29, 2028 must reach 82% thermal efficiency (10 CFR 430.32(k)(1)).
  2. CaliforniaCalifornia 2025 Energy Code takes effectPool heating permits applied for from this date need a heat pump, solar on at least 60% of a single-family pool surface, or 60% renewable or recovered energy as the primary heat (Title 24 Section 110.4(c)).
  3. RebateCenterPoint Energy Indiana heat pump rebate window closesHeat pump pool heaters bought and installed Jan 1 to Dec 31, 2026 qualify: $350 at COP 5.5 to 5.9, $800 at COP 6.0 or more.
  4. Air districtSouth Coast AQMD zero-NOx pool heaters, new buildingsRule 1146.2 Phase II: pool heaters up to 400,000 Btu/h sold or installed for new buildings must meet a 0 ppmv NOx limit.
  5. FederalDOE 2028 pool heater standardsGas TEI = 84(Q + 491)/(Q + 2,536), 83.32% at 250,000 Btu/h; the electric level DOE adopted is one that no electric resistance pool heater in its analysis met.
  6. Air districtSouth Coast AQMD zero-NOx pool heaters, existing buildingsRule 1146.2 Phase II reaches replacements at existing homes; residential units are exempt from the unit-age retirement rule.

DOE’s 2028 formula for gas heaters, 84 x (input + 491) / (input + 2,536), works out to 83.32% at 250,000 Btu/h, a step up from today’s 82% (DOE final rule, 88 FR 34624). For electric pool heaters DOE adopted a level that no electric resistance heater in its analysis met, so new electric models made from that date are in practice heat pumps. Our gas pool heater rules registry tracks the federal, state, air district and city rules in one place.

Can you add a pool heater to an existing pool, and is it worth it?

Yes: a heater plumbs into the return line after the filter, so most existing pools can take one; cost turns on whether gas or a 50 A circuit already reaches the pad. Worth depends on use. EIA found 35.8% of US pool homes heated the pool in 2024, and heat from a heat pump cost about a third of gas heat at July 2026 prices.

Worked arithmetic: hours to raise 10,000 and 20,000 gallons by 20 F, before heat losses
HeaterOutput to the water (Btu/h)Hours to raise 10,000 gal by 20 FHours to raise 20,000 gal by 20 FOutput source
Gas, 400,000 Btu/h input at 84%336,0005.09.9Pentair MasterTemp 400 rating
Gas, 250,000 Btu/h input at 84%210,0007.915.9Pentair MasterTemp 250 rating
Heat pump at 80 F air (Hayward HP31005T)100,00016.733.4Hayward HeatPro manual
Same heat pump at 50 F air61,00027.354.7Hayward HeatPro manual

Sources: formula hours = gallons x 8.34 x rise / output (Pentair Engineering Data, via our sizing guide); outputs from Pentair MasterTemp ratings (84%) and the Hayward HeatPro manual (100,000 Btu/h at 80 F air, 61,000 at 50 F); PC&S calculation. Download CSV

A 400,000 Btu/h gas heater lifts 10,000 gallons by 20 F in about 5.0 hours; a 100,000 Btu/h heat pump takes 16.7 hours in 80 F air and 27.3 hours in 50 F air. That speed is what the gas line buys. Per unit of heat the order flips: at July 2026 US prices, delivered gas heat cost $31.14 per MMBtu against $10.73 for a heat pump at a COP of 5.0 (PC&S cost to heat a pool study, EIA prices).

In EIA’s 2024 survey, 35.8% of the 9.6 million US homes with a pool heated it, and 70.3% of heated pools were heated for three months or less (PC&S study). For short seasons in sunny states, a solar system may pay back faster; see our solar pool heater guide. For a spa or hot tub on its own heater, the electricity math is in our hot tub electricity cost guide.

Gas heater or heat pump: which installation fits your yard?

Pick the fuel your site already supports unless local rules or daily use point the other way. A like-for-like gas swap on an existing line is the cheapest install at about $3,804 to $8,450. A heat pump costs more to install but less to run, needs 50 F air to work well and a 45 to 50 A circuit.

Decision table: pool heater installation path by situation
If your situation isDo thisWhy (source)
Gas already runs to the equipment pad and the heater is a like-for-like swapPrice a swap: heater, labor, permit and haul-away, about $3,804 to $8,450Shelf prices plus Angi labor and permit ranges; Homewyse puts a 150,000 Btu/h replacement at $2,760 to $4,530 (May 2026)
A new gas heater sits 50 to 100 ft from the meterBudget 1-1/4 in pipe for 250,000 to 400,000 Btu/h and add every other gas appliance on that lineIFGC Table 402.4(2) and Section 402.2; Hayward Table 10
You heat daily, cover the pool and swim when air is 50 F or warmerChoose a heat pump and confirm the panel has room for a 2-pole, 45 to 50 A breakerHayward MCA 42 A, 45 A breaker; Pentair UltraTemp 40 to 50 A
There is no gas service at the houseCompare a heat pump circuit with a propane tank and line; propane pipe can run a size smallerPentair MasterTemp guide: low-pressure LP pipe may be 1/4 in smaller, 1/2 in minimum
You live in the South Coast AQMDBuy a heat pump, or a gas heater only if it is installed before the zero-NOx datesRule 1146.2: Jan 1, 2028 for new buildings, Jan 1, 2031 for existing
You are in California and the permit is for new pool heatingMake a heat pump or solar the primary heat; gas only as backupTitle 24 Section 110.4(c), permits applied for from Jan 1, 2026
Your utility runs a heat pump rebateCheck the COP floor before you buyCenterPoint Energy Indiana: $350 at COP 5.5 to 5.9, $800 at 6.0 or more (2026)

Sources: Homewyse; IFGC 402.2 and Table 402.4(2); Hayward Table 10; Hayward HeatPro manual; Pentair UltraTemp guide; Pentair MasterTemp guide; SCAQMD Rule 1146.2; Title 24 Section 110.4(c); CenterPoint Energy Indiana; PC&S line items. Download CSV

Installation path flowchart: local heat pump rules first, then daily use and 50 F air, then gas line distance. Built from SCAQMD Rule 1146.2, Title 24, Hayward and Pentair manuals, IFGC Table 402.4(2), Angi and 2026 shelf prices.
Installation path flowchart: local heat pump rules first, then daily use and 50 F air, then gas line distance. Built from SCAQMD Rule 1146.2, Title 24, Hayward and Pentair manuals, IFGC Table 402.4(2), Angi and 2026 shelf prices.

How we compiled this

We opened 17 primary documents in October 2026: installation manuals from Hayward (Universal H-Series, HeatPro) and Pentair (MasterTemp, UltraTemp), the 2021 IFGC gas pipe tables as adopted by Seattle, fee schedules from Miami-Dade and Palm Beach counties, a CenterPoint Energy rebate form, Pentair’s rebate page, BLS wage data, and the federal, SCAQMD and California rule texts held in our rules registry. Shelf prices are dated retailer captures from our price index; labor and line-cost ranges are from Angi and HomeAdvisor, cited as such. We did not install or test heaters, and the totals are our sums of those sources.

Frequently Asked Questions

How much does it cost to install a heater on a pool?

About $3,804 to $8,450 for a gas heater swapped onto an existing gas line, and $5,425 to $8,549 for a heat pump on an existing circuit, using 2026 shelf prices plus Angi’s labor and permit ranges. New gas lines or circuits raise the top to $11,800. Angi’s national average across all heater types is $3,038 (March 2026).

Can you add a pool heater to an existing pool?

Yes. The heater goes in the return line after the filter, with any chlorinator downstream and a check valve between them (Pentair; Hayward). The cost depends on utilities at the pad: a gas line runs about $15 to $25 a foot (Angi), and a heat pump needs a 208 to 230 V circuit with a 40 to 50 A breaker.

How long will it take to heat a 10,000 gallon pool?

About 5.0 hours to raise 10,000 gallons by 20 F with a 400,000 Btu/h gas heater at 84% efficiency, before heat losses (gallons x 8.34 x rise / output). A 100,000 Btu/h heat pump takes about 16.7 hours in 80 F air and 27.3 hours in 50 F air, from Hayward’s ratings. Covering the pool cuts the losses that stretch these times. Loss-adjusted times for covered and uncovered pools are worked out in our guide to how long it takes to heat a pool.

Is it worth installing a pool heater?

It is if you will use the extra weeks. EIA found 35.8% of US pool homes heated the pool in 2024, most for three months or less. A heat pump cost about $10.73 per MMBtu of heat at July 2026 prices against $31.14 for gas, so daily heating favors a heat pump, while weekend spot heating favors gas speed.

How much does it cost to install a gas pool heater?

About $3,804 to $8,450 on an existing gas line: a $3,179 to $6,399.99 heater, $500 to $1,500 labor, a $100 to $500 permit and $25 to $50 removal. A new 50 ft line adds $750 to $1,250 at $15 to $25 a foot, with 1-1/4 in pipe for a 400,000 Btu/h heater (IFGC Table 402.4(2)).

How much does it cost to install a pool heat pump?

About $5,425 to $8,549 on an existing circuit and $5,675 to $10,649 with a new one, for a 138,000 to 140,000 Btu/h unit priced at $4,800 to $6,999 in 2026. The circuit must match the label, for example a 42 A minimum circuit ampacity and 45 A breaker for Hayward’s HP31005T. Some utilities rebate $350 to $800.

Sources

  1. Angi. How Much Does a Pool Heater Cost to Install? (archived Apr 18, 2026; updated Mar 17, 2026). Accessed 2026-10-27.
  2. Angi. How Much Do Gas Line Installation or Repairs Cost? (archived Mar 28, 2026; updated Mar 17, 2026). Accessed 2026-10-27.
  3. HomeAdvisor. Pool Heater Installation Cost (archived Aug 14, 2025; updated Apr 30, 2025). Accessed 2026-10-27.
  4. Homewyse. Cost to Replace Pool Heater (May 2026). Accessed 2026-10-27.
  5. City of Seattle / International Code Council. 2021 Seattle Fuel Gas Code, Chapter 4 (IFGC 2021 Tables 402.4(1) and 402.4(2), Section 402.2). Accessed 2026-10-27.
  6. Hayward. Universal H-Series Service & Installation Manual, Rev T. Accessed 2026-10-27.
  7. Hayward. HeatPro Heat Pump Installation and Operation Manual 51300056501 Rev G. Accessed 2026-10-27.
  8. Pentair. MasterTemp Pool and Spa Heater Installation and User's Guide. Accessed 2026-10-27.
  9. Pentair. UltraTemp Heat Pump Installation and User's Guide. Accessed 2026-10-27.
  10. Miami-Dade County. Implementing Order 4-63, Building and Neighborhood Compliance fees, effective Oct 1, 2026. Accessed 2026-10-27.
  11. Palm Beach County. Planning, Zoning and Building Fees (printed Mar 2, 2026). Accessed 2026-10-27.
  12. U.S. Bureau of Labor Statistics. Occupational Employment and Wage Statistics, May 2025 (API series for SOC 47-2152 and 47-2111). Accessed 2026-10-27.
  13. CenterPoint Energy. 2026 Indiana residential heat pump pool heater rebate application. Accessed 2026-10-27.
  14. Pentair. Pentair Pool Product Rebates. Accessed 2026-10-27.
  15. eCFR. 10 CFR 430.32(k), pool heater standards. Accessed 2026-10-27.
  16. U.S. Department of Energy. Energy Conservation Standards for Consumer Pool Heaters, 88 FR 34624 (May 30, 2023). Accessed 2026-10-27.
  17. South Coast AQMD. Rule 1146.2 (amended June 7, 2024). Accessed 2026-10-27.
  18. California Energy Commission. 2025 Building Energy Efficiency Standards, Title 24 Part 6. Accessed 2026-10-27.
  19. California Energy Commission. Energy Code Support Center FAQ. Accessed 2026-10-27.
  20. Leslie's. Raypak 009219 listing (Wayback capture Jun 6, 2026). Accessed 2026-10-27.
  21. Leslie's. Pentair MasterTemp 460775 listing (Wayback capture Sep 16, 2026). Accessed 2026-10-27.
  22. Leslie's. Raypak Crosswind V 8550 listing (Wayback capture Jun 30, 2026). Accessed 2026-10-27.
  23. Walmart.com. Hayward W3HP21404T listing (captured Oct 14, 2026). Accessed 2026-10-27.
  24. Pool Construction & Service. Pool Equipment Prices 2026 (price index). Accessed 2026-10-27.
  25. Pool Construction & Service. Cost to Heat a Pool: Gas Heater vs Heat Pump by State, 2026. Accessed 2026-10-27.
  26. Pool Construction & Service. Gas Pool Heater Ban Registry. Accessed 2026-10-27.