How to Prime a Pool Pump, and What to Do When It Keeps Losing Prime
How to prime a pool pump: turn off power, fill the strainer pot to the suction port, seat a clean lid O-ring, open the filter air relief valve, then restart and expect prime within 5 to 15 minutes.
- ✓Quoted from 9 maker manualsHayward, Pentair and Jandy manuals, with document numbers, behind every step and time limit.
- ✓Troubleshooting in check orderA decision table and flowchart built from the makers' own Pump Won't Prime lists.
- ✓IndependentPC&S sells no pumps or parts. We connect owners with licensed pool service companies.
Key takeaways
- Every manual we read starts the same way: water in the strainer pot up to the suction port, a clean seated lid O-ring and the filter’s air relief valve open (Pentair IntelliFlo3 guide; Hayward Super Pump manual).
- Hayward’s Super Pump manual says priming may take up to 10 minutes and to stop and find the cause if the pump has not primed within 5 minutes (Hayward 1017836 Rev A).
- Pentair’s IntelliFlo3 ships with an 11 minute maximum priming duration and says never to run longer than 30 minutes without successfully priming (Pentair P/N 356231).
- At 10 feet above the water, Jandy’s VS FloPro takes about 14 to 15 minutes to prime at its 2,750 RPM default but should prime within 6 minutes at 3,450 RPM (Jandy H0661800 Rev C).
- Hayward, Pentair and Jandy manuals allow in-ground pumps up to 10 feet above the water, but Jandy recommends installing within 2 feet and a suction check valve above that (Jandy H0315300 Rev U).
What does priming a pool pump mean?
Priming means filling the pump’s strainer pot and impeller housing with water so the impeller can pull a vacuum and draw water up the suction line. A self-priming pool pump, such as the Hayward Super Pump, then clears the air from that line on its own, as long as the pot holds water and no air leaks in. That water also cools and lubricates the shaft seal.
| Number | What it means | Source |
|---|---|---|
| 10 ft | Highest the pump may sit above the pool water: Pentair SuperFlo, SuperFlo VS and IntelliFlo3; Hayward Super Pump self-primes to 10 ft; Jandy pumps are NSF-certified to 10 ft at sea level | Pentair P/N 356968, 356292, 356231; Hayward 1017836; Jandy H0315300, H0661800 |
| 1 to 2 ft | Jandy's recommended install height above the water (VS FloPro within 1 ft, FloPro within 2 ft); VS FloPro no higher than 5 ft | Jandy H0661800 Rev C; H0315300 Rev U |
| 1.8 m (5.9 ft) | Hayward Super II ECO (Australia): highest suction lift at which it still primes without a check valve | Hayward Super II ECO manual |
| Up to 10 min | Hayward Super Pump priming time; stop and find the cause if no prime within 5 minutes | Hayward 1017836 Rev A |
| 8 min | Hayward TriStar XE automatic prime at maximum speed | Hayward IS3200XE Rev B |
| 5 min at 3,450 RPM | Pentair SuperFlo VS priming cycle; speed adjustable down to 1,700 RPM, below which priming is disabled | Pentair P/N 356292 Rev A |
| 11 min and 30 min | Pentair IntelliFlo3 default maximum priming duration; never run longer than 30 minutes without prime | Pentair P/N 356231 Rev E |
| 14 to 15 min vs 6 min | Jandy VS FloPro at 10 ft of lift: 2,750 RPM default vs 3,450 RPM | Jandy H0661800 Rev C |
| 5 to 6 in of vacuum | What a healthy Hayward Super Pump should pull at the strainer cover with the suction blocked | Hayward 1017836 Rev A |
| Halfway up the skimmer opening | Pool water level Pentair calls proper; below the opening the pump draws air | Pentair P/N 356292, 356231 |
| 5 seconds | Hayward: wait before restarting to avoid reverse rotation | Hayward 1017836 Rev A |
Sources: Pentair IntelliFlo3 VSF guide; Pentair SuperFlo guide; Pentair SuperFlo VS guide; Hayward Super Pump manual; Hayward TriStar XE manual; Hayward Super II ECO manual; Jandy FloPro manual; Jandy VS FloPro manual. Accessed October 26, 2026. Download CSV
Never let the pump run dry. Hayward says water is the coolant and lubricant for the mechanical shaft seal, and running dry may damage the seal, cause leaks and void the warranty (Hayward Super Pump manual). Pentair’s SuperFlo guide adds that a seal damaged this way must be replaced. Federal efficiency rules call these machines self-priming pool filter pumps (10 CFR 431.465). Water dripping under the motor after a dry run is that seal, and the replacement steps and seal prices by model are in our pool pump leaking guide.
How do you prime a pool pump? Step by step
Shut off power, relieve filter pressure, fill the strainer pot to the suction port, seat a clean lid O-ring, open the valves and the filter’s air relief valve, stand clear and restart. The steps below follow the Pentair IntelliFlo3 and Hayward Super Pump manuals; the model table after them shows where Hayward, Pentair and Jandy differ on time limits and lubricant.
- Turn the pump off at the breakerPentair’s step 1. On a variable speed pump, wait at least 60 seconds for the drive’s stored charge before servicing.
- Check the water levelPool water should sit halfway up the skimmer opening (Pentair). Lower water lets the pump draw air.
- Close valves if the pump is below the waterPentair says close the suction and return lines before opening the pot when the pump sits below the pool level.
- Relieve pressureOpen the filter’s air relief valve and stand clear until the gauge reads 0 psi (Pentair step 3).
- Open the lid, empty the basket, fill the potFill the strainer pot up to the suction port with a bucket or hose (Pentair step 5; Hayward: to suction pipe level).
- Clean and seat the lid O-ringWipe the O-ring and its seat. Hayward lubricates it with Jack’s 327 every time; Jandy warns against Vaseline. Hand-tighten only, no wrenches.
- Open all suction and return valvesPentair step 7. A multiport valve goes on FILTER, changed only with the pump off (Hayward VariFlo).
- Stand clear and restartHayward says stand at least 10 feet from the pump and filter when starting. Variable speed pumps run their priming cycle automatically.
- Bleed the airClose the air relief valve when a steady stream of water, not air, comes out (Pentair; Hayward).
- Time itHayward: up to 10 minutes, check the cause after 5. Pentair IntelliFlo3: never over 30 minutes. Refill the pot and retry before troubleshooting.
| Pump (manual) | Type | Fill before start | Priming time or limit | Height above water | Lid O-ring care | Source |
|---|---|---|---|---|---|---|
| Hayward Super Pump (1017836 Rev A) | Single speed or 2-speed | Strainer housing to suction pipe level | Up to 10 min; find the cause if no prime within 5 min | Self-priming to 10 ft (2-speed: high speed only) | Clean and lubricate with Jack's 327 each time; hand-tighten knobs, no wrenches | Hayward |
| Hayward TriStar XE (IS3200XE Rev B) | Variable speed | Strainer housing to suction pipe level | Automatic 8 min prime at maximum speed; stop if no prime within 10 min | Not stated in the priming section | Lubricate with Jack's 327 if necessary | Hayward |
| Hayward PowerFlo Matrix (ISSP1591 Rev H) | Above-ground, single speed | Strainer housing to suction pipe level | Stop if no prime within 10 min | Locate below the pool water line | Jack's 327 each time removed; hand-tighten 1/4 turn | Hayward |
| Pentair SuperFlo (P/N 356968 Rev C) | Single speed | Pump pot and volute up to the inlet port | Not stated | No more than 10 ft; elbow or valve at least 5 pipe diameters from the inlet | Keep clean and well lubricated; seat before clamping | Pentair |
| Pentair SuperFlo VS (P/N 356292 Rev A) | Variable speed | Pump filled with water | 5 min at 3,450 RPM by default; 1,700 to 3,450 RPM | No more than 10 ft | Keep clean and well lubricated | Pentair |
| Pentair IntelliFlo3 VSF (P/N 356231 Rev E) | Variable speed | Strainer pot up to the suction port | 11 min default maximum; never over 30 min | No more than 10 ft (3.1 m) | Properly seated, not pinched between lid and pot | Pentair |
| Jandy FloPro FHPM (H0315300 Rev U) | Single speed | Above water: remove lid and fill basket | Not stated; check for a suction leak if no prime | NSF-certified to 10 ft; install within 2 ft; check valve above 2 ft | Clear debris from the O-ring seat; hand-tighten, no tools | Jandy (Zodiac) |
| Jandy VS FloPro (H0661800 Rev C) | Variable speed | Fill with water before start | About 14 to 15 min at 2,750 RPM, within 6 min at 3,450 RPM (10 ft of lift) | Within 1 ft recommended; no more than 5 ft | Section 5: soapy water only; troubleshooting chart: very small amount of silicone lubricant, no Vaseline | Jandy (Zodiac) |
Sources: Hayward 1017836 Rev A; Hayward IS3200XE Rev B; Hayward ISSP1591 Rev H; Pentair P/N 356968 Rev C; Pentair P/N 356292 Rev A; Pentair P/N 356231 Rev E; Jandy H0315300 Rev U; Jandy H0661800 Rev C. Accessed October 26, 2026. Download CSV

What is the best way to prime a pool pump? The way your manual describes, because makers disagree on the details. Hayward wants the lid O-ring lubricated with Jack’s 327 every time it comes off, while Jandy’s VS FloPro manual says soapy water only in its service section and a very small amount of silicone lubricant, never Vaseline, in its troubleshooting chart. Hayward and Jandy both say to tighten the lid by hand, with no wrenches or tools.
Does it matter if the pump sits above or below the pool water?
Yes. A pump below the water line floods as soon as the valves open, so it primes itself, but you must close the suction and return valves before opening the lid. A pump above the water has to lift water, so the pot must be filled by hand before every start. Jandy recommends installing within 1 to 2 feet of the water level for easier priming.
| Step | Pump below the pool water level (flooded suction) | Pump above the pool water level (suction lift) | Source |
|---|---|---|---|
| Before opening the lid | Close the suction and return valves first or the pool drains out through the pot | Stop the pump and release filter pressure | Pentair SuperFlo; Hayward Super Pump |
| Getting water into the pot | Opening the valves floods the pump; it primes itself | Fill the pot or basket with water by hand to the suction port | Hayward Super Pump; Jandy FloPro 4.1.1 and 4.1.2 |
| Air relief | Open the filter air relief valve; close it at a steady stream of water | Same | Jandy FloPro; Pentair IntelliFlo3 |
| Valves the installer must provide | Isolation valves on both suction and return lines (Jandy VS FloPro) | Check valve on the suction line when more than 2 ft above the water (Jandy FloPro) | Jandy H0661800; H0315300 |
| Typical failure | Prime lost only if air gets in on the suction side | Prime lost while off if water drains back with no check valve | Jandy FloPro; Hayward Super II ECO |
Sources: Pentair SuperFlo; Hayward Super Pump; Jandy FloPro; Jandy VS FloPro; Pentair IntelliFlo3; Hayward Super II ECO. Download CSV
Source: Sources: Pentair P/N 356231, 356968, 356292; Hayward 1017836 Rev A and Super II ECO manual (1.8 m converted at 3.28 ft per m); Jandy H0315300 Rev U and H0661800 Rev C. Accessed October 26, 2026.. Download chart data (CSV)
Hayward’s Australian Super II ECO manual sets the highest suction lift at which that pump still primes without a check valve at 1.8 metres, about 5.9 feet, while the U.S. Hayward and Pentair manuals cite 10 feet. Jandy recommends a suction-line check valve once a FloPro sits more than 2 feet above the water, to keep the plumbing full while the pump is off. A pump that loses prime overnight is the symptom that check valve prevents.
How long does a pool pump take to prime?
A few minutes in most cases, longer with more lift and a longer suction pipe. Hayward’s Super Pump manual allows up to 10 minutes, the Hayward TriStar XE runs an automatic 8 minute prime at maximum speed, and Pentair’s SuperFlo VS primes at 3,450 RPM for 5 minutes. Jandy’s VS FloPro needs about 14 to 15 minutes with 10 feet of lift at its default speed.
IntelliFlo3: 11 minutes is the default maximum priming duration and 30 minutes the never-exceed limit.
Source: Sources: Pentair P/N 356292 Rev A and 356231 Rev E; Hayward 1017836 Rev A, IS3200XE Rev B, ISSP1591 Rev H; Jandy H0661800 Rev C. Accessed October 26, 2026.. Download chart data (CSV)

| Priming speed (Jandy VS FloPro, pump 10 ft above the water) | Minutes to prime (manual) | Speed as share of 3,450 RPM | Power as share of 3,450 RPM (speed cubed) | Energy to prime, in full-speed minutes |
|---|---|---|---|---|
| 2,750 RPM (factory default) | 14 to 15 | 0.797 | 0.506 | 7.09 to 7.60 |
| 3,450 RPM | 6 | 1.000 | 1.000 | 6.00 |
| Difference | 8 to 9 minutes faster at 3,450 RPM | 3,450 RPM uses about 15% to 21% less energy to prime |
PC&S arithmetic. Minutes from Jandy H0661800 Rev C; power scaled by the cube of speed under the pump affinity laws (Engineering ToolBox). Download CSV
Faster priming saves energy in Jandy’s own numbers. Under the affinity laws, pump power scales with the cube of speed, so 2,750 RPM draws about 51% of the power of 3,450 RPM. Over 14 to 15 minutes that still adds up to more energy than 6 minutes at full speed: full speed uses about 15% to 21% less. The affinity laws describe water flow, not a pump clearing air, so treat the result as an estimate. Low-speed programming for daily filtration is covered in our variable speed pool pump guide, and yearly running costs by state are in our cost to run a pool pump report.
Why won't my pool pump prime? Troubleshooting table
The Hayward, Pentair and Jandy troubleshooting charts trace a pump that will not prime to five problems: no water in the pot, air leaking in on the suction side, water too low at the skimmer, a closed valve, or a clog in the baskets, suction line or impeller. Check them in that order, cheapest first, before anyone opens the pump.
| If your situation is | Likely cause | Do this | Manual |
|---|---|---|---|
| Strainer pot empty, or bubbles at the lid | No priming water, or a dry, dirty or cracked lid O-ring | Fill the pot to the suction port; clean, lubricate as your maker says and reseat the O-ring; hand-tighten | Hayward Super Pump; Jandy VS FloPro |
| Water below halfway up the skimmer opening, skimmer gurgling | Pump is drawing air through the skimmer | Raise the water to halfway up the skimmer opening, then reprime | Pentair SuperFlo VS; IntelliFlo3 |
| A suction or return valve closed, or multiport on CLOSED | No flow path | Turn the pump off, open every valve or set the multiport to FILTER, then restart | Hayward VariFlo; IntelliFlo3 steps 2 and 7 |
| Pump or skimmer basket full of debris | Restricted suction | Empty both baskets and refill the strainer housing | Hayward Super Pump |
| Bubbles from the return fittings in the pool wall | Suction air leak at unions, valve O-rings or packing glands | Tighten unions, repair or replace valves, re-tape threads with PTFE tape | Hayward Super Pump |
| Pump pulls a vacuum but moves little water | Blocked suction line or clogged impeller | Check the line; open the housing and clear the impeller | Hayward Super Pump |
| Variable speed pump primes slowly or never ramps up | Priming disabled or priming speed set too low | Enable priming; raise priming speed (below 1,700 RPM the SuperFlo VS skips priming) | Pentair SuperFlo VS; Jandy VS FloPro |
| Pump sits over 2 ft above the water and loses prime overnight | Water drains back while the pump is off | Add a suction-line check valve | Jandy FloPro; Hayward Super II ECO |
| Motor hums but does not start | Impeller jammed with debris | Call a qualified repair professional | Hayward Super Pump |
| Pump ran dry and the pot is hot | Vapor pressure and scalding water inside | Do not open until cool, with valves open; then replace the shaft seal if it leaks | Pentair SuperFlo |
Sources: Hayward Super Pump troubleshooting; Pentair SuperFlo; Pentair SuperFlo VS; Pentair IntelliFlo3; Jandy FloPro; Jandy VS FloPro; Hayward VariFlo valve; Hayward Super II ECO. Download CSV


Hayward’s blocked-suction test separates a leak from a clog: a healthy pump should pull 5 to 6 inches of vacuum at the strainer cover, which only a dealer’s vacuum gauge confirms (Hayward Super Pump manual). As a rough home check, Hayward suggests holding a hand over the skimmer’s bottom port with the skimmer full and the pump running; no suction points to a blocked line.
Why does my pool pump keep losing prime?
A pump that loses prime while running is drawing air: low water at the skimmer, a leaking lid O-ring, or a loose union, valve stem or drain plug on the suction side. A pump that loses prime only while it is off is draining back, usually because it sits above the water with no check valve. Hayward notes that suction leaks show up as bubbles at the return fittings.
- Lid O-ring and lid Cracked, flattened or dry O-rings and debris on the seat let air in (Hayward; Jandy).
- Unions and threaded fittings Hayward says tighten unions and re-seal threads with PTFE tape when bubbles come from the returns.
- Valve O-rings and packing glands Leaking valves on the suction side are item 3 on Hayward’s Pump Won’t Prime list.
- Water level and skimmer Below the skimmer opening, the pump draws air and runs dry (Pentair).
- Vacuum hose An unprimed vacuum hose pushes air into the pump (Pentair); fill the hose under water first.
- Check valve Losing prime only while off means water drains back; Jandy recommends a check valve above 2 feet.
EPA’s WaterSense pool guide lists the pump seal and pipe joints among common leak points and treats air bubbles in the return line or the pump strainer as a leak sign; losing more than 2 inches of water a week, or 3 inches in hot, dry areas, likely means a leak (EPA WaterSense, 2022). Our pool leak detection guide covers the bucket test, and hose priming is in our guide on how to vacuum a pool.
Is it safe to open and prime a pool pump?
It is routine work, but the manuals list real hazards. A filter system under pressure can separate violently, so Hayward says open the filter’s air relief valve and stand at least 10 feet away when starting. Never open a pot that ran dry and feels hot, never purge lines with compressed air, and keep the pump on a GFCI-protected circuit, as Hayward requires.
| Hazard | What the manual says to do | Source |
|---|---|---|
| Filter or pump separating under pressure | Open all valves and the filter air relief valve before starting; stand at least 10 feet from the pump and filter | Hayward Super Pump 1017836 Rev A |
| Stored electrical charge in a variable speed drive | Wait at least 60 seconds after power-off before servicing | Pentair IntelliFlo3 P/N 356231 |
| Scalding water after a dry run | Do not open the strainer pot until it is cool to the touch, with suction and discharge valves open | Pentair SuperFlo P/N 356968 |
| Purging lines with compressed air | Never; use only a low pressure blower under 5 PSI | Hayward Super Pump 1017836 Rev A |
| Electric shock | Connect only to a GFCI-protected circuit and test the GFCI routinely | Hayward Super Pump 1017836 Rev A |
| Reverse rotation on restart | Wait 5 seconds before restarting the pump | Hayward Super Pump 1017836 Rev A |
| Chemical damage to the pump | Do not add undiluted chemicals to the system directly in front of the pump | Pentair IntelliFlo3 P/N 356231 |
Sources: Hayward Super Pump manual; Pentair IntelliFlo3 guide; Pentair SuperFlo guide. Accessed October 26, 2026. Download CSV
When should you call a pool technician?
Call when the pump still will not prime after two full attempts within the manual’s time limit and every check in the table passes, when the motor hums but does not start, when water leaks at the shaft seal, or when the pump ran dry and the pot is hot. Hayward routes a jammed impeller and a clogged suction line to a qualified repair professional.
Ask the technician to run a vacuum test at the strainer cover and to pressure-test the suction line, and ask for the price of a lid O-ring or seal kit before any talk of replacement. If replacement does come up, our pool pump replacement cost guide prices pumps, motors and housings, and the pool repair guide covers other pump faults. A pump that hums, trips the breaker or shows a fault code is traced symptom by symptom, with the Hayward, Pentair and Jandy fixes, in our pool pump not working guide.
How we compiled this
We read 8 pump manuals from Hayward, Pentair and Jandy (Zodiac Pool Systems), Hayward’s VariFlo multiport valve manual, EPA’s WaterSense pool guide, CPSC’s pool electrocution data and an affinity-law reference, all accessed in October 2026. Steps, time limits and heights are quoted from the manuals with their document numbers; the priming energy comparison is PC&S arithmetic. We did not test any pump, and forum posts were used only for question wording.
Frequently Asked Questions
What is the best way to prime a pool pump?
Follow your model’s manual: power off, release filter pressure, fill the strainer pot to the suction port, seat a clean lid O-ring, open the valves and the filter air relief valve, then restart while standing clear. Hayward expects prime within up to 10 minutes; Pentair’s IntelliFlo3 sets an 11 minute default limit and a 30 minute hard stop.
How to fix a pool pump that won't prime?
Work from cheapest to hardest: refill the pot, clean and reseat the lid O-ring, raise the water to halfway up the skimmer opening, open every valve, empty the baskets, then look for suction leaks, which Hayward says show as bubbles at the return fittings. If the motor hums without starting, Hayward says a jammed impeller needs a repair professional.
How do I get the air out of my pool pump?
Open the filter’s manual air relief valve before starting and close it when a steady stream of water, not air, comes out, as the Pentair and Hayward manuals direct. Air that keeps returning to the pot means a suction-side leak, most often the lid O-ring, a union or low water at the skimmer. Never purge lines with compressed air; Hayward allows only a blower under 5 PSI.
How long does a pool pump take to prime?
Most manuals allow 5 to 15 minutes. Hayward’s Super Pump may take up to 10 minutes, Hayward’s TriStar XE primes for 8 minutes at full speed, Pentair’s SuperFlo VS runs a 5 minute priming cycle, and Jandy’s VS FloPro needs about 14 to 15 minutes at 10 feet of lift at its default 2,750 RPM, or 6 minutes at 3,450 RPM.
Why would a pool pump keep losing prime?
Air is getting in or water is draining out. While running, the usual causes are water below the skimmer opening, a leaking lid O-ring or a loose union on the suction side. If prime is lost only while the pump is off, water is draining back; Jandy recommends a suction check valve when a FloPro sits more than 2 feet above the water.
How do you prime a pool pump that is higher than the pool?
Fill the strainer pot by hand before every start, keep the lid O-ring sealed and allow time: Jandy’s VS FloPro takes about 14 to 15 minutes with 10 feet of lift at its default speed. Pentair and Hayward manuals cap the height at 10 feet above the water, and Jandy recommends a check valve above 2 feet.
Sources
- Hayward. Super Pump Series Owner's Manual, 1017836 Rev A. Accessed 2026-10-26.
- Hayward. TriStar XE Pump Series Owner's Manual, IS3200XE Rev B. Accessed 2026-10-26.
- Hayward. PowerFlo Matrix Pump Owner's Manual, ISSP1591 Rev H. Accessed 2026-10-26.
- Hayward Pool Products Australia. Super II ECO Single Speed Pump manual (Australia). Accessed 2026-10-26.
- Hayward. VariFlo Multiport Valve Owner's Manual, IS0710X62 Rev B. Accessed 2026-10-26.
- Pentair. SuperFlo High Performance Pump Installation and User's Guide, P/N 356968 Rev C (7/31/23). Accessed 2026-10-26.
- Pentair. SuperFlo VST, SuperFlo VS and SuperMax VS Installation and User's Guide, P/N 356292 Rev A (7/10/20). Accessed 2026-10-26.
- Pentair. IntelliFlo3 VSF / IntelliPro3 VSF Installation and Maintenance Guide, P/N 356231 Rev E (6/30/25). Accessed 2026-10-26.
- Zodiac Pool Systems (Jandy). FloPro (FHP) Series Pumps Installation and Operation Manual, H0315300 Rev U. Accessed 2026-10-26.
- Zodiac Pool Systems (Jandy). VS FloPro Variable-Speed Pumps Installation and Operation Manual, H0661800 Rev C (dealer-hosted copy). Accessed 2026-10-26.
- eCFR. 10 CFR 431.465, Dedicated-purpose pool pump energy conservation standards. Accessed 2026-10-26.
- U.S. Environmental Protection Agency. Jump Into Pool Water Efficiency (WaterSense, September 2022). Accessed 2026-10-26.
- U.S. Consumer Product Safety Commission. Don't Swim with Shocks: Electrical Safety In and Around Pools, Spas and Hot Tubs. Accessed 2026-10-26.
- Engineering ToolBox. Affinity Laws for Pumps. Accessed 2026-10-26.