Skip to content
Still backyard pool on an overcast day with leaves floating on the surface
Pool equipment guide: troubleshooting

Pool Pump Not Working? Symptom-by-Symptom Fixes From the Hayward, Pentair and Jandy Manuals

Pool pump not working? Check power first: Hayward's manual starts with tripped breakers, GFCIs, timers and loose wiring, then a jammed impeller if the motor hums. Seal and bearing repairs run $100 to $350 (Angi, 2025).

Free Pool Quote Match

Tell us about your pool project. We match you with licensed local pros who cover your area.

Step 1 of 3: Your project

Free for homeownersNo obligationAbout 60 seconds

  • ✓9 manuals, one symptom tableCauses and fixes quoted from Hayward, Pentair, Jandy and Little Giant troubleshooting sections, with document numbers.
  • ✓Variable speed fault codes decodedTriStar XE flash codes, SuperFlo VS codes and IntelliFlo3 alarms with the maker's fix.
  • ✓Repair or replace, with dated pricesCapacitor, seal, bearing, motor and new pump costs side by side, plus a worked example.
Quick answer
Most failed pool pumps have a power, jam or heat problem. Check the breaker, GFCI and timer first; a humming motor points to a jammed impeller or failed capacitor; a pump that runs then stops is tripping its thermal overload or a drive fault. Repairs run $100 to $700 (Angi); a new variable speed pump about $1,839 to $2,139.
$100 to $250 / $150 to $350
Seal / bearing repair
Within 10% of data plate
Motor voltage tolerance
$1,839 to $2,139
New VS pump installed

Key takeaways

  • Hayward’s Super Pump manual lists the checks for a motor that will not start in this order: wiring and voltage, tripped breakers, GFCIs or fuses, a shaft that turns freely, then the timer (Hayward 1017836 Rev A).
  • A motor that hums but does not start has an impeller jammed with debris in Hayward’s chart; with power off, a shaft that turns freely by hand points instead to the capacitor (Inyo Pools).
  • Jandy says voltage at the running motor must be within 10% of the data plate rating, and a pump that gets hot and shuts off needs room around the motor and a voltage check (Jandy FloPro H0315300 Rev U).
  • Pentair’s IntelliFlo3 restarts itself 1 minute after an over-current fault, and a GFCI that trips without its test button means ground current is flowing: do not use the pump (Pentair P/N 356231 Rev E).
  • Angi puts a shaft seal repair at $100 to $250, bearings at $150 to $350 and a motor at $350 to $700 (Angi, Nov 2025), against $1,839 to $2,139 for a new variable speed pump installed in 2026.
  • A Little Giant APCP-1700 cover pump switches on at 2.5 in of water and off at 1 in; an air lock, a dirty float or a frozen hose are the first things its manual checks (Little Giant 998295 Rev 06).

Why is my pool pump not working? Start with the symptom

Name what the pump is doing, then follow that row: silent, humming, running then stopping, running without flow, noisy, tripping the breaker, showing a fault code or ignoring its timer. The table below takes every cause and fix from the troubleshooting sections of Hayward, Pentair and Jandy manuals, and marks the point where the job moves to a licensed pro.

Pool pump not working: symptom, cause, owner check and when to call a pro, from the maker manuals
SymptomLikely causes the manuals listOwner check (power off first)Call a pro whenManual
Will not start, silentTripped breaker or GFCI, blown fuse, open switch, relay or timer, loose wiring, motor wired for the wrong voltageReset the breaker once; confirm the timer or automation is calling for the pump; bypass a mechanical timer only if you know howBreaker or GFCI trips again, or wiring at the terminal board looks loose or burnedHayward Super Pump 1017836 Rev A; Pentair SuperFlo VS 356292
Hums but does not startImpeller jammed with debris; failed start or run capacitor on single-speed motors; seized bearingsWith power off, check the shaft turns by hand at the motor rearShaft will not turn, or a capacitor needs testing (stored charge)Hayward Super Pump; Hayward TriStar XE; Inyo Pools capacitor guide
Runs, then shuts offLow voltage from undersized wire or an extension cord; thermal overload after overheating; blocked cooling fanClear leaves and debris from the motor fan cover; give the motor room to breatheMeasured voltage is outside 10% of the data plate, or it keeps cyclingHayward Super Pump; Jandy FloPro; Pentair IntelliFlo3
Runs but no flow or low flowNo prime, air leak on the suction side, full baskets, closed valve, dirty filter, clogged impellerFill the pot, empty baskets, open valves, check filter pressureImpeller needs clearing inside the pump, or a suction line is blockedHayward Super Pump; Pentair SuperFlo VS; Jandy VS FloPro
Loud, rattling or gravel noiseCavitation from restricted suction or low water, debris hitting the impeller, loose mountingRaise water level, clean baskets, tighten mounting boltsNoise stays after baskets and water level are fixedHayward Super Pump; Pentair IntelliFlo3
Screech or whineWorn bearings, often after a shaft seal leak lets chlorinated water wash out the greaseLook for water under the motorAny shaft seal leak: Hayward says replace it at onceHayward Super Pump; Pentair IntelliFlo3
Trips breaker or GFCIGround fault in motor or wiring; GFCI tripping without the test button means ground current is flowingDo not reset repeatedly; keep everyone out of the waterAlways: Pentair says do not use the pump until a qualified service representative corrects itPentair IntelliFlo3; Hayward PowerFlo Matrix
Display shows a fault codeOver-temperature, over-current, voltage out of range, stalled motor, internal drive fault, lost communicationNote the code, cut power at the breaker for 30 to 60 seconds, restoreCode returns after a power cycleHayward TriStar XE; Pentair IntelliFlo3; Pentair SuperFlo VS; Jandy VS FloPro
Timer or schedule does not start itClock dial stopped, tripper loose, wrong time of day, worn timer switch; VS schedule or automation address wrongCheck the dial turns and the ON and OFF trippers are tight; check the pump schedule or automationTimer needs rewiring or the automation link has failedInyo Pools T104 guide; Hayward Super Pump; Jandy VS FloPro

Sources: Hayward Super Pump 1017836 Rev A; Hayward TriStar XE IS3200XE Rev B; Pentair IntelliFlo3 P/N 356231 Rev E; Pentair SuperFlo VS P/N 356292 Rev A; Jandy VS FloPro H0661800 Rev C; Hayward PowerFlo Matrix ISSP1591 Rev H; Jandy FloPro H0315300 Rev U; Inyo Pools capacitor guide; Inyo Pools T104 guide. Accessed November 2, 2026. Download CSV

Symptom flowchart: tripped breaker or tingle means stop and call an electrician; silent means check the power path; humming means check the shaft; runs then stops means heat or voltage. Built from Hayward 1017836 Rev A, Pentair 356231 Rev E and Jandy H0661800 Rev C.
Symptom flowchart: tripped breaker or tingle means stop and call an electrician; silent means check the power path; humming means check the shaft; runs then stops means heat or voltage. Built from Hayward 1017836 Rev A, Pentair 356231 Rev E and Jandy H0661800 Rev C.
Key numbers for a pool pump that is not working, with source
NumberWhat it meansSource
Within 10%Voltage at the running motor must be within 10% of the data plate ratingJandy FloPro H0315300 Rev U; VS FloPro H0661800 Rev C; Hayward TriStar XE
1 minutePentair SuperFlo VS and IntelliFlo3 restart on their own after an over-temperature or over-current faultPentair P/N 356292 Rev A; P/N 356231 Rev E
30 secondsWait for the LED to go fully off before reapplying power to a Hayward TriStar XEHayward IS3200XE Rev B
5 flash codesHayward TriStar XE LED: 1 voltage, 2 current, 3 drive heat, 4 stalled, 5 internal failureHayward IS3200XE Rev B
99 VPentair SuperFlo VS fault 0F: supply dropped below its operating rangePentair P/N 356292 Rev A
230 VACCharge a Pentair IntelliFlo3 drive capacitor bank holds even with power offPentair P/N 356231 Rev E
$100 to $350Seal ($100 to $250) and bearing ($150 to $350) repairsAngi, updated Nov 25, 2025
7 yearsDOE mean lifetime for residential self-priming pool pumpsDOE, 82 FR 5650 (2017)
2.5 in on, 1 in offWater depth at which a Little Giant APCP-1700 cover pump switches on and offLittle Giant manual 998295 Rev 06

Sources: Hayward Super Pump 1017836 Rev A; Hayward TriStar XE IS3200XE Rev B; Pentair IntelliFlo3 P/N 356231 Rev E; Pentair SuperFlo VS P/N 356292 Rev A; Jandy VS FloPro H0661800 Rev C; Jandy FloPro H0315300 Rev U; Angi; DOE, 82 FR 5650; Little Giant 998295 Rev 06. Download CSV

Why won't my pool pump turn on at all?

A silent pump usually has no power reaching it. Hayward’s chart lists loose wiring, open switches or relays, tripped breakers, GFCIs and blown fuses first, then a motor wired for the wrong voltage, then the timer. On variable speed pumps, Pentair adds a locked or damaged motor shaft, and Jandy adds wrong low-voltage wiring or pump address when automation runs it.

  1. Look at the breaker and any GFCIReset a tripped breaker or GFCI once. If it trips again, stop: Pentair says a GFCI that trips on its own means ground current is flowing and the pump must not be used until a qualified service representative corrects it.
  2. Check what calls the pumpA mechanical timer’s dial should be turning and its ON and OFF trippers tight; an automation system or the pump’s own schedule may simply be off. Hayward’s step 3: if you have a timer, make sure it works, and bypass it if necessary.
  3. Read the display or LEDA variable speed pump with a blinking LED or code is protecting itself; match the code in the fault code table further down this page before anything else.
  4. Power off, then turn the shaftHayward says to check the motor shaft for free movement. A shaft that will not turn means a jam or seized bearings; one that turns but will not start under power points to the capacitor on single-speed motors.
  5. Hand it to an electricianTerminal board connections must match the wiring diagram on the motor data plate and the supply voltage (Hayward). Voltage checks at a live motor are work for a licensed electrician.

Extension cords are a common culprit and a hazard. Hayward’s Super Pump manual says low voltage at the motor is frequently caused by undersized wiring or extension cord use, and its above-ground PowerFlo Matrix manual says do not use an extension cord at all (Hayward ISSP1591 Rev H). CPSC data on cords and outlets near pools are in our pool electrocution statistics.

Pool pump timer not working? On an Intermatic T104, the yellow clock dial should spin, the green ON and gold OFF trippers should be screwed tight at the times you want, and the dial must be set to the time of day. Inyo Pools’ install guide wires line power to terminals 1 and 3 and the pump to 2 and 4 (Inyo Pools). A replacement T104M mechanism listed at $79.95 on November 2, 2026.

Variable speed pumps keep their own schedule, so a timer is often the wrong suspect. Pentair’s IntelliFlo3 ships with a Program 1 of 24 hours at 30 GPM, and Jandy’s VS FloPro will not start under automation if DIP switches 3 and 4 set the wrong pump address (Jandy H0661800 Rev C). Controllers and their schedules are compared in our pool automation system guide.

Why is my pool pump humming and not working?

Hum without rotation means the motor has power but cannot turn. Hayward’s chart names an impeller jammed with debris; on single-speed and two-speed motors a failed start or run capacitor does the same. Turn the power off and try the shaft by hand: if it turns freely, suspect the capacitor; if it will not turn, the impeller or bearings are seized.

Humming pool pump: what each check points to
Check (power off at the breaker)ResultWhat it points toSource
Turn the motor shaft by hand (rear of motor or through the fan cover)Turns freelyFailed capacitor on a single-speed or two-speed motorInyo Pools, Test a Pool Pump Capacitor (2017)
Turn the motor shaft by handWill not turnImpeller jammed with debris, or seized bearingsHayward Super Pump 1017836 Rev A; Inyo Pools
Open the strainer lid, look into the impeller eyeLeaves, pebbles or hair packed inJammed impeller; Hayward says have a qualified repair professional open the pumpHayward Super Pump; Jandy VS FloPro blocked impeller steps
Look at the capacitor (single-speed motors only)Bulged, leaking or burnedReplace with the same MFD rating and equal or higher voltageInyo Pools capacitor guide
Variable speed pump shows a stalled-motor codeHayward TriStar XE: 4 flashesDrive could not start the motor: check impeller, diffuser, shaft seal and motor for bindingHayward IS3200XE Rev B

Sources: Hayward Super Pump 1017836 Rev A; Hayward TriStar XE IS3200XE Rev B; Jandy VS FloPro H0661800 Rev C; Inyo Pools, Test a Pool Pump Capacitor (Sept 6, 2017). Download CSV

Capacitors store a charge after the power is off. Inyo Pools’ guide says to discharge one across its terminals with an insulated screwdriver, with eye protection and a cloth over it, because shorted capacitors have been known to explode (Inyo Pools). Replace it with the same MFD rating and equal or higher voltage: a 440 V part can replace a 370 V one. Run capacitors of 30 to 50 MFD at 370 V listed at $22.95 to $39.95 on November 2, 2026.

Variable speed pumps have no start capacitor to blame; their drive reports the problem. Hayward’s TriStar XE flashes 4 times when the drive could not start the motor and points to the impeller, diffuser, shaft seal and motor for binding (Hayward IS3200XE Rev B). Jandy’s blocked-impeller steps start with the breaker off, then lid and basket out, then debris cleared by hand.

Pool pump running but no water flow, or it keeps losing prime?

A pump that runs without moving water has lost prime or is starved on the suction side. Pentair’s SuperFlo VS chart lists a loose impeller, air in the suction line or pump, and clogged plumbing or a dirty filter. Hayward adds full baskets, a closed valve and a suction leak that shows as bubbles at the return fittings in the pool wall.

Work from cheapest to hardest. Fill the strainer pot to the suction port, empty the pump and skimmer baskets, open every valve, and raise the water to the middle of the skimmer opening. Hayward expects a healthy Super Pump to pull 5 to 6 inches of vacuum at the strainer cover with the suction blocked (Hayward 1017836 Rev A). Step-by-step priming limits for 8 pump models are in our guide on how to prime a pool pump.

Clear water after a fix: once the pump primes and moves water again, filtration and sanitizer levels recover over the next turnovers.
Clear water after a fix: once the pump primes and moves water again, filtration and sanitizer levels recover over the next turnovers.

If the fan at the rear of a Pentair SuperFlo VS spins but no water moves, Pentair says to open the pump and check the impeller is correctly installed (Pentair 356292 Rev A). Jandy’s FloPro chart adds worn impellers and diffusers when there is no air in the system and pressure is still low, and on a new installation it asks for a voltage check within 10% of the data plate.

Why is my pool pump making noise?

The sound tells you the cause. Rattling like gravel is cavitation from a starved suction side or low water; knocking is debris hitting the impeller; a buzz with vibration is a loose mount; a screech or whine is bearings. Hayward ties bearing noise to seal leaks that let chlorinated water wash out the grease, and says replace any leaking seal at once.

Pool pump noises, causes and fixes from the manuals
What you hearCause in the manualsFixManual
Gravel or marbles rattlingCavitation: restricted or undersized suction, low pool water, air leakRaise water, clean baskets, correct the suction side or throttle returnsHayward Super Pump
Knocking or clatterLoose stones or debris hitting the impellerClean the pump housingHayward Super Pump
Buzz with vibrationPump not level or not secured to the padMount level and bolt to the pad; tighten mounting boltsHayward Super Pump; Pentair SuperFlo VS
Screech or whineBearings worn by age, rust, heat or chlorinated water after a seal leakReplace the leaking seal at once; bearings or motor by a proHayward Super Pump
Fan tickingDebris touching the cooling fanClean the fan cover with compressed airPentair IntelliFlo3; Pentair SuperFlo VS
Loud at high speed onlyMotor speed set higher than neededReduce speed if possiblePentair IntelliFlo3

Sources: Hayward Super Pump 1017836 Rev A; Pentair IntelliFlo3 P/N 356231 Rev E; Pentair SuperFlo VS P/N 356292 Rev A. Download CSV

Hayward's own troubleshooting page: Motor Will NOT Start, Motor Hums But Does NOT Start, and Noisy Pump, including the bearing and seal note. Hayward Super Pump Owner's Manual 1017836 Rev A, page 10, accessed November 2, 2026; boxes added by PC&S.
Hayward’s own troubleshooting page: Motor Will NOT Start, Motor Hums But Does NOT Start, and Noisy Pump, including the bearing and seal note. Hayward Super Pump Owner’s Manual 1017836 Rev A, page 10, accessed November 2, 2026; boxes added by PC&S.

Catch the seal before the bearings. A Hayward SPX1600Z2 shaft seal listed at $19.95 and a Pentair IntelliFlo3 seal at $29.95 on November 2, 2026, and Angi puts a seal replacement at $100 to $250 installed against $150 to $350 for bearings (Angi). Hayward notes its pumps have self-lubricating bearings and seals, so no grease is ever added. If the noise comes with water under the motor, our pool pump leaking guide maps six leak points to the maker’s fix and a dated part price.

Why does my pool pump shut off, trip the breaker or show a fault code?

Shutting off on its own is protection, not failure. Hayward’s motors carry an automatic thermal overload that cuts out before the windings burn and restarts once cool, and Pentair’s variable speed drives stop on over-temperature or over-current and retry after 1 minute. A breaker or GFCI that trips is different: it can mean a ground fault, so the pool stays closed until an electrician checks it.

Variable speed pool pump fault codes and what the maker says to do
PumpCode or alertWhat it meansWhat the manual says to do
Hayward TriStar XE1 flashDC voltage out of rangeCheck line voltage is within 10% of the rating at the terminal block and the voltage jumper is set right
Hayward TriStar XE2 flashesMotor current too highCheck impeller, diffuser, shaft seal and motor for binding
Hayward TriStar XE3 flashesDrive (IPM) temperature too highClear the motor airflow path; check ambient temperature against the nameplate
Hayward TriStar XE4 flashesPump has stalledCheck impeller, diffuser, shaft seal and motor for binding
Hayward TriStar XE5 flashesInternal motor or drive failureContact Hayward Technical Service; the motor and drive may need replacing
Pentair SuperFlo VS21Lost link between keypad and motor controlCheck the 5-pin connector and cable on the back of the drive
Pentair SuperFlo VS02Power module over-currentIf repeated, inspect impeller and shaft seal
Pentair SuperFlo VS0FSupply voltage below 99 VOften clears itself; otherwise check wiring and supply voltage
Pentair IntelliFlo3 VSFOverheat / Drive is DeratingHigh internal temperature; pump slows itselfClean the fan guard; resumes when cool
Pentair IntelliFlo3 VSFOver CurrentLoad rose: debris, part interference, age, voltageInspect rotating parts for blockage; restarts after 1 minute
Pentair IntelliFlo3 VSFOver / Under VoltageSupply voltage outside rangeClears when voltage returns to normal
Pentair IntelliFlo3 VSFPriming FailureNo water in the strainer basketFill the pot; adjust priming speed and duration
Pentair IntelliFlo3 VSFInternal FaultDrive hardware or software errorDisconnect power, reconnect after 1 minute; if it remains, call a qualified pool professional
Jandy VS FloProPump not connectedLow-voltage wiring or pump address (DIP switches 3 and 4) wrongCheck the controller wiring and DIP switch settings in section 3.3

Sources: Hayward TriStar XE IS3200XE Rev B; Pentair SuperFlo VS P/N 356292 Rev A; Pentair IntelliFlo3 P/N 356231 Rev E; Jandy VS FloPro H0661800 Rev C. Download CSV

Heat shutdowns follow the same causes across makers. Jandy says a pump that gets hot and shuts off periodically needs room for air around the motor and a voltage check within 10% of its data plate (Jandy); Pentair’s IntelliFlo3 flags a blocked cooling fan or high ambient temperature and slows itself first. Hayward’s XE wants 30 seconds with the LED fully off before power is restored.

Trips are the electrical question. CPSC knows of 33 electrocution deaths in US pools and spas from 2002 to 2018 (CPSC), and the 2020 NEC requires GFCI protection when a pool pump motor is replaced (NEC 680.21(D), as printed in the 2020 NEC pool requirements a Connecticut town publishes). Our pool bonding guide covers the bonding an inspector checks; a repeat trip is a licensed electrician’s job, not a reset-and-retry job.

Pool cover pump not working? What the cover pump manual says

Safety and winter covers that hold water need a cover pump, and the Little Giant APCP-1700 is a common one: 1/3 HP, 115 V, switching on at 2.5 in of water and off at 1 in. Its manual traces a pump that will not start to the plug, breaker or a dirty float, and a pump that runs without pumping to an air lock, a blocked or frozen hose, or too much lift.

Pool cover pump not working: Little Giant APCP-1700 troubleshooting
Cover pump problemProbable causeFixSource
Does not turn onNot plugged in, breaker off, trash on the float, float obstructionPlug in, reset breaker, remove the float access cover and clean the floatLittle Giant APCP-1700 manual 998295 Rev 06
Does not turn on, upside-down test worksClogged switchRemove the blue lid and clean buildupLittle Giant APCP-1700 FAQ
Runs but does not pumpAir lock, kinked or blocked hose, frozen hose, lift too highPower off about 1 minute and restart, repeat; clean the vent hole; clear or thaw the hoseLittle Giant manual
Will not shut offFloat obstruction, air lock, inflow exceeds pump outputClean the float; clear the air lock; add pump capacityLittle Giant manual
Cycles on and offNo check valve on a long discharge so water drains back onto the cover; clogged voluteInstall a check valve in the discharge line; clean screen and basketLittle Giant manual
Thermal protector tripsAir lock, obstructed impeller, high or low voltage, worn motorLet it cool, clear the air lock and impeller, check voltage; replace if worn outLittle Giant manual
Motor buzzesInternal motor problemReplace the pump; the cord and switch are not replaceable partsLittle Giant APCP-1700 FAQ

Sources: Little Giant APCP-1700 Owner Manual 998295 Rev 06 (03/25); Little Giant APCP-1700 FAQ. Accessed November 2, 2026. Download CSV

Little Giant APCP-1700 cover pump flow by lift heightGallons per hour from the maker's flow table; maximum height 26 ft
Little Giant APCP-1700 cover pump flow by lift heightBar chart: the Little Giant APCP-1700 pumps 1,745 gallons per hour at 1 ft of lift, 1,230 at 10 ft and 490 at 20 ft.05001,0001,5002,0001 ft: 1,7451 ft5 ft: 1,5405 ft10 ft: 1,23010 ft15 ft: 85015 ft20 ft: 49020 ft

Source: Little Giant APCP-1700 Owner's Manual 998295 Rev 06 (03/25), accessed November 2, 2026.. Download chart data (CSV)

Lift and hose size decide the flow. Little Giant rates the APCP-1700 at 1,745 gallons per hour at 1 ft of lift and 490 at 20 ft, with a 26 ft maximum, and recommends a 1 in inside-diameter hose (Little Giant). The manual also says to plug it into a GFCI-protected outlet and not to let it freeze. Solid covers are compared in our pool safety cover guide.

Standing water on a solid cover is the job a cover pump does; the Little Giant APCP-1700 switches on at 2.5 in of water and off at 1 in.
Standing water on a solid cover is the job a cover pump does; the Little Giant APCP-1700 switches on at 2.5 in of water and off at 1 in.

Repair or replace a pool pump that is not working?

Repair when the fault is a part and the pump is young: a capacitor with an hour of labor runs about $98 to $190, a seal $100 to $250 and bearings $150 to $350. Replace when the housing is cracked, the motor is gone on a single-speed pump past DOE’s 7-year mean life, or a variable speed drive shows an internal failure code.

Pool pump repair vs replacement costs, with part prices and dates
FixPart price (retailer, date)Installed or repair cost (source)When it fits
Run capacitor, single-speed motor$22.95 to $39.95 for 30 to 50 MFD, 370 V (ePoolSupply, Nov 2, 2026)Technician time at $75 to $150 an hour (Angi, Nov 2025)Motor hums, shaft turns freely by hand
Shaft seal$19.95 Hayward SPX1600Z2; $29.95 Pentair IntelliFlo3 356210S (ePoolSupply, Nov 2, 2026)$100 to $250 (Angi, Nov 2025)Water dripping under the motor; do it before bearings fail
BearingsVaries by motor$150 to $350 (Angi, Nov 2025)Screech or whine, seal leak caught late
Motor replacement$667.99 to $895.95 for a 1.65 HP Century VGreen 165 variable speed motor (Oct 19, 2026)$350 to $700 (Angi); $200 to $800, $500 average (HomeAdvisor, June 2026)Housing and impeller sound; motors of 1.15 to 5 THP made since Sept 29, 2025 must be variable speed
Variable speed motor plus labor$667.99 to $895.95$767.99 to $1,295.95 (part + $100 to $400 labor)Old single-speed motor failed
Whole variable speed pump$1,739 median list, 1.5 to 1.65 THP (2026)$1,839 to $2,139 before any permitCracked housing, pump past DOE's 7-year mean life

Sources: Angi (Nov 25, 2025); HomeAdvisor (June 19, 2026); ePoolSupply (Nov 2, 2026); INYOPools (Oct 19, 2026); 10 CFR 431.485; DOE, 82 FR 5650; PC&S pool pump replacement cost guide. Download CSV

Pool pump repair vs replacement cost, 2026Published repair ranges and PC&S totals from dated part prices
Pool pump repair vs replacement cost, 2026Range chart: a capacitor with an hour of labor costs about $98 to $190, a seal $100 to $250, bearings $150 to $350, a motor $350 to $700, a variable speed motor with labor $768 to $1,296 and a new variable speed pump $1,839 to $2,139.$0$625$1,250$1,875$2,500Capacitor + 1 h labor: $98.0 to $190Capacitor + 1 h laborShaft seal (Angi): $100 to $250Shaft seal (Angi)Bearings (Angi): $150 to $350Bearings (Angi)Motor replacement (Angi): $350 to $700Motor replacement (Angi)VS motor + labor: $768 to $1,296VS motor + laborNew VS pump installed: $1,839 to $2,139New VS pump installed

Source: Angi (Nov 25, 2025); ePoolSupply (Nov 2, 2026); INYOPools and The Pool Supply Warehouse (Oct 19, 2026); PC&S pool pump replacement cost guide.. Download chart data (CSV)

Worked example: a 9-year-old single-speed pump that hums
LineItemAmountSource
19-year-old single-speed pump hums, shaft turns: capacitor part$22.95 to $39.95ePoolSupply, Nov 2, 2026
2One hour of technician time to test and fit it$75 to $150Angi (Nov 2025)
3Capacitor repair total (1 + 2)$97.95 to $189.95PC&S arithmetic
4New variable speed pump installed instead$1,839 to $2,139PC&S pool pump replacement cost guide
5Yearly electricity saving, single-speed to variable speed, median state (North Carolina)$487PC&S cost to run a pool pump report (EIA July 2026, DOE seasons)
6Extra cost of replacing now (4 minus 3)$1,649.05 to $2,041.05PC&S arithmetic
7Years for the saving to cover line 6 (6 / 5)3.4 to 4.2 yearsPC&S arithmetic
8Pump age against DOE's 7-year mean life2 years pastDOE, 82 FR 5650

Sources: ePoolSupply; Angi; PC&S cost to run a pool pump report (EIA July 2026, DOE seasons); DOE, 82 FR 5650. PC&S arithmetic. Download CSV

In the worked example the capacitor is the cheap fix, but the pump is 2 years past DOE’s mean life, so the next fault is near. Replacing now costs $1,649.05 to $2,041.05 more and pays back in 3.4 to 4.2 years in the median state, faster where electricity costs more. Line-item installed prices are in our pool pump replacement cost guide, and speed settings in our variable speed pool pump guide.

Decision table: what to do about a pool pump that is not working
If your situation isDo thisNumber behind it
Breaker or GFCI trips, or anyone feels a tingle in the waterKeep power off and people out of the pool; call a licensed electricianCPSC: 33 electrocution deaths in US pools and spas, 2002 to 2018
Pump is silent and the breaker is onCheck the timer, automation schedule and relay before the motorHayward lists switches, relays and timers ahead of the motor
Hums, shaft turns by hand, single-speed motor under 7 years oldReplace the capacitor$22.95 to $39.95 part; $97.95 to $189.95 with an hour of labor
Hums, shaft will not turnClear the impeller or replace bearings, by a proBearings $150 to $350 (Angi)
Leak under the motor, no noise yetReplace the shaft seal nowSeal $100 to $250 installed (Angi); part $19.95 to $29.95
Motor failed, housing sound, pump under 8 yearsFit a variable speed replacement motor$767.99 to $1,295.95 with labor; single-speed motors of 1.15 to 5 THP made since Sept 29, 2025 are not allowed
Single-speed pump older than 7 years with any motor faultPrice a whole variable speed pump$1,839 to $2,139 installed; $487 a year saved in the median state
Variable speed pump shows the same fault code after a power cycleCall the maker's technical service or a pool pro; ask about drive warrantyHayward TriStar XE 5 flashes = internal motor or drive failure

Sources: CPSC; Hayward 1017836 Rev A; Hayward IS3200XE Rev B; Angi; 10 CFR 431.485; DOE, 82 FR 5650; ePoolSupply and INYOPools listings. Download CSV

How we compiled this

On November 2, 2026 we read the troubleshooting sections of 9 manuals: Hayward Super Pump, TriStar XE and PowerFlo Matrix; Pentair IntelliFlo3, SuperFlo VS and SuperFlo; Jandy FloPro and VS FloPro; and the Little Giant APCP-1700, plus Little Giant’s FAQ, an Inyo Pools capacitor guide and CPSC’s pool shock page. Part prices are ePoolSupply listings from that day; repair costs come from Angi and HomeAdvisor. We did not test any pump, and forum posts were excluded.

Frequently Asked Questions

Why is my pool pump not working?

Usually power, a jam or heat. Hayward’s Super Pump manual checks wiring, tripped breakers, GFCIs, fuses and the timer first, then whether the shaft turns freely. A humming motor points to a jammed impeller or failed capacitor, and a pump that runs then stops is often tripping its automatic thermal overload from low voltage or poor airflow.

Why is my pool pump humming and not working?

The motor has power but cannot turn. Hayward lists an impeller jammed with debris; on single-speed motors a failed capacitor causes the same hum. With the breaker off, turn the shaft by hand: if it spins freely, suspect the capacitor ($22.95 to $39.95 for a 30 to 50 MFD part); if it is stuck, the impeller or bearings need a pro.

How do I reset my pool pump?

Turn it off at the breaker, wait, then restore power. Hayward’s TriStar XE needs 30 seconds with the LED fully off; Pentair’s IntelliFlo3 manual says disconnect power and reconnect after 1 minute for an internal fault. If a breaker or GFCI trips again after one reset, leave it off and call a licensed electrician.

Why does my pool pump keep shutting off?

Most pumps protect themselves from heat. Hayward’s motors carry an automatic thermal overload that restarts once cool, and Jandy says a pump that gets hot and shuts off needs air space around the motor and voltage within 10% of its data plate. Pentair’s variable speed drives stop on over-temperature or over-current and retry after 1 minute.

How do I know if my pool pump motor is bad?

Signs in the manuals: a screech or whine from bearings, a hum with a shaft that will not turn, a variable speed drive that shows an internal failure code (5 flashes on a Hayward TriStar XE) or repeated over-current faults. A motor replacement runs $350 to $700 (Angi), and a variable speed motor part $667.99 to $895.95.

Why is my pool cover pump not working?

On a Little Giant APCP-1700, check the plug and breaker, then clean the float, which switches the pump on at 2.5 in of water and off at 1 in. If it runs without pumping, clear an air lock by switching off for about 1 minute and restarting, and check the hose for kinks or ice. A buzzing motor means replacement.

Sources

  1. Hayward. Super Pump Series Owner's Manual, 1017836 Rev A. Accessed 2026-11-02.
  2. Hayward. TriStar XE Pump Series Owner's Manual, IS3200XE Rev B. Accessed 2026-11-02.
  3. Hayward. PowerFlo Matrix Pump Owner's Manual, ISSP1591 Rev H. Accessed 2026-11-02.
  4. Pentair. IntelliFlo3 VSF / IntelliPro3 VSF Installation and Maintenance Guide, P/N 356231 Rev E. Accessed 2026-11-02.
  5. Pentair. SuperFlo VST, SuperFlo VS and SuperMax VS Installation and User's Guide, P/N 356292 Rev A. Accessed 2026-11-02.
  6. Pentair. SuperFlo High Performance Pump Installation and User's Guide, P/N 356968 Rev C. Accessed 2026-11-02.
  7. Zodiac Pool Systems (Jandy). FloPro (FHP) Series Pumps Installation and Operation Manual, H0315300 Rev U. Accessed 2026-11-02.
  8. Zodiac Pool Systems (Jandy). VS FloPro Variable-Speed Pumps Installation and Operation Manual, H0661800 Rev C (dealer-hosted copy). Accessed 2026-11-02.
  9. Little Giant (Franklin Electric). APCP-1700 Automatic Pool Cover Pump Owner's Manual, 998295 Rev 06 (03/25). Accessed 2026-11-02.
  10. Little Giant. APCP-1700 technical support FAQ. Accessed 2026-11-02.
  11. Inyo Pools. How to Test a Pool Pump Capacitor (Sept 6, 2017). Accessed 2026-11-02.
  12. Inyo Pools. How to Install an Intermatic T104 Timer. Accessed 2026-11-02.
  13. Angi. How Much Does It Cost to Repair a Pool Pump? (Nov 25, 2025, Wayback copy). Accessed 2026-11-02.
  14. HomeAdvisor. Install or replace a pool pump cost (June 19, 2026). Accessed 2026-11-02.
  15. ePoolSupply. Part listings: shaft seals, capacitors, T104M time switch. Accessed 2026-11-02.
  16. INYOPools. Century VGreen 165 ECM16SQU listing (Oct 19, 2026). Accessed 2026-11-02.
  17. eCFR. 10 CFR 431.485, pool pump motor standards. Accessed 2026-11-02.
  18. U.S. Department of Energy. Energy Conservation Standards for Dedicated-Purpose Pool Pumps, 82 FR 5650. Accessed 2026-11-02.
  19. U.S. Energy Information Administration. Electric Power Monthly Table 5.6.A (July 2026). Accessed 2026-11-02.
  20. Town of Woodbury, CT. 2020 National Electrical Code in-ground pool requirements (NEC 680.21(D)). Accessed 2026-11-02.
  21. U.S. Consumer Product Safety Commission. Don't Swim with Shocks: Electrical Safety In and Around Pools. Accessed 2026-11-02.
Free for homeowners

Get Quotes From Licensed Local Pool Pros

Tell us what you need and your ZIP code. We match you with pool companies that cover your area.