Pool pump not working? Check power first: Hayward's manual starts with tripped breakers, GFCIs, timers and loose wiring, then a jammed impeller if the motor hums. Seal and bearing repairs run $100 to $350 (Angi, 2025).
- ✓9 manuals, one symptom tableCauses and fixes quoted from Hayward, Pentair, Jandy and Little Giant troubleshooting sections, with document numbers.
- ✓Variable speed fault codes decodedTriStar XE flash codes, SuperFlo VS codes and IntelliFlo3 alarms with the maker's fix.
- ✓Repair or replace, with dated pricesCapacitor, seal, bearing, motor and new pump costs side by side, plus a worked example.
Key takeaways
- Hayward’s Super Pump manual lists the checks for a motor that will not start in this order: wiring and voltage, tripped breakers, GFCIs or fuses, a shaft that turns freely, then the timer (Hayward 1017836 Rev A).
- A motor that hums but does not start has an impeller jammed with debris in Hayward’s chart; with power off, a shaft that turns freely by hand points instead to the capacitor (Inyo Pools).
- Jandy says voltage at the running motor must be within 10% of the data plate rating, and a pump that gets hot and shuts off needs room around the motor and a voltage check (Jandy FloPro H0315300 Rev U).
- Pentair’s IntelliFlo3 restarts itself 1 minute after an over-current fault, and a GFCI that trips without its test button means ground current is flowing: do not use the pump (Pentair P/N 356231 Rev E).
- Angi puts a shaft seal repair at $100 to $250, bearings at $150 to $350 and a motor at $350 to $700 (Angi, Nov 2025), against $1,839 to $2,139 for a new variable speed pump installed in 2026.
- A Little Giant APCP-1700 cover pump switches on at 2.5 in of water and off at 1 in; an air lock, a dirty float or a frozen hose are the first things its manual checks (Little Giant 998295 Rev 06).
Why is my pool pump not working? Start with the symptom
Name what the pump is doing, then follow that row: silent, humming, running then stopping, running without flow, noisy, tripping the breaker, showing a fault code or ignoring its timer. The table below takes every cause and fix from the troubleshooting sections of Hayward, Pentair and Jandy manuals, and marks the point where the job moves to a licensed pro.
| Symptom | Likely causes the manuals list | Owner check (power off first) | Call a pro when | Manual |
|---|---|---|---|---|
| Will not start, silent | Tripped breaker or GFCI, blown fuse, open switch, relay or timer, loose wiring, motor wired for the wrong voltage | Reset the breaker once; confirm the timer or automation is calling for the pump; bypass a mechanical timer only if you know how | Breaker or GFCI trips again, or wiring at the terminal board looks loose or burned | Hayward Super Pump 1017836 Rev A; Pentair SuperFlo VS 356292 |
| Hums but does not start | Impeller jammed with debris; failed start or run capacitor on single-speed motors; seized bearings | With power off, check the shaft turns by hand at the motor rear | Shaft will not turn, or a capacitor needs testing (stored charge) | Hayward Super Pump; Hayward TriStar XE; Inyo Pools capacitor guide |
| Runs, then shuts off | Low voltage from undersized wire or an extension cord; thermal overload after overheating; blocked cooling fan | Clear leaves and debris from the motor fan cover; give the motor room to breathe | Measured voltage is outside 10% of the data plate, or it keeps cycling | Hayward Super Pump; Jandy FloPro; Pentair IntelliFlo3 |
| Runs but no flow or low flow | No prime, air leak on the suction side, full baskets, closed valve, dirty filter, clogged impeller | Fill the pot, empty baskets, open valves, check filter pressure | Impeller needs clearing inside the pump, or a suction line is blocked | Hayward Super Pump; Pentair SuperFlo VS; Jandy VS FloPro |
| Loud, rattling or gravel noise | Cavitation from restricted suction or low water, debris hitting the impeller, loose mounting | Raise water level, clean baskets, tighten mounting bolts | Noise stays after baskets and water level are fixed | Hayward Super Pump; Pentair IntelliFlo3 |
| Screech or whine | Worn bearings, often after a shaft seal leak lets chlorinated water wash out the grease | Look for water under the motor | Any shaft seal leak: Hayward says replace it at once | Hayward Super Pump; Pentair IntelliFlo3 |
| Trips breaker or GFCI | Ground fault in motor or wiring; GFCI tripping without the test button means ground current is flowing | Do not reset repeatedly; keep everyone out of the water | Always: Pentair says do not use the pump until a qualified service representative corrects it | Pentair IntelliFlo3; Hayward PowerFlo Matrix |
| Display shows a fault code | Over-temperature, over-current, voltage out of range, stalled motor, internal drive fault, lost communication | Note the code, cut power at the breaker for 30 to 60 seconds, restore | Code returns after a power cycle | Hayward TriStar XE; Pentair IntelliFlo3; Pentair SuperFlo VS; Jandy VS FloPro |
| Timer or schedule does not start it | Clock dial stopped, tripper loose, wrong time of day, worn timer switch; VS schedule or automation address wrong | Check the dial turns and the ON and OFF trippers are tight; check the pump schedule or automation | Timer needs rewiring or the automation link has failed | Inyo Pools T104 guide; Hayward Super Pump; Jandy VS FloPro |
Sources: Hayward Super Pump 1017836 Rev A; Hayward TriStar XE IS3200XE Rev B; Pentair IntelliFlo3 P/N 356231 Rev E; Pentair SuperFlo VS P/N 356292 Rev A; Jandy VS FloPro H0661800 Rev C; Hayward PowerFlo Matrix ISSP1591 Rev H; Jandy FloPro H0315300 Rev U; Inyo Pools capacitor guide; Inyo Pools T104 guide. Accessed November 2, 2026. Download CSV

| Number | What it means | Source |
|---|---|---|
| Within 10% | Voltage at the running motor must be within 10% of the data plate rating | Jandy FloPro H0315300 Rev U; VS FloPro H0661800 Rev C; Hayward TriStar XE |
| 1 minute | Pentair SuperFlo VS and IntelliFlo3 restart on their own after an over-temperature or over-current fault | Pentair P/N 356292 Rev A; P/N 356231 Rev E |
| 30 seconds | Wait for the LED to go fully off before reapplying power to a Hayward TriStar XE | Hayward IS3200XE Rev B |
| 5 flash codes | Hayward TriStar XE LED: 1 voltage, 2 current, 3 drive heat, 4 stalled, 5 internal failure | Hayward IS3200XE Rev B |
| 99 V | Pentair SuperFlo VS fault 0F: supply dropped below its operating range | Pentair P/N 356292 Rev A |
| 230 VAC | Charge a Pentair IntelliFlo3 drive capacitor bank holds even with power off | Pentair P/N 356231 Rev E |
| $100 to $350 | Seal ($100 to $250) and bearing ($150 to $350) repairs | Angi, updated Nov 25, 2025 |
| 7 years | DOE mean lifetime for residential self-priming pool pumps | DOE, 82 FR 5650 (2017) |
| 2.5 in on, 1 in off | Water depth at which a Little Giant APCP-1700 cover pump switches on and off | Little Giant manual 998295 Rev 06 |
Sources: Hayward Super Pump 1017836 Rev A; Hayward TriStar XE IS3200XE Rev B; Pentair IntelliFlo3 P/N 356231 Rev E; Pentair SuperFlo VS P/N 356292 Rev A; Jandy VS FloPro H0661800 Rev C; Jandy FloPro H0315300 Rev U; Angi; DOE, 82 FR 5650; Little Giant 998295 Rev 06. Download CSV
Why won't my pool pump turn on at all?
A silent pump usually has no power reaching it. Hayward’s chart lists loose wiring, open switches or relays, tripped breakers, GFCIs and blown fuses first, then a motor wired for the wrong voltage, then the timer. On variable speed pumps, Pentair adds a locked or damaged motor shaft, and Jandy adds wrong low-voltage wiring or pump address when automation runs it.
- Look at the breaker and any GFCIReset a tripped breaker or GFCI once. If it trips again, stop: Pentair says a GFCI that trips on its own means ground current is flowing and the pump must not be used until a qualified service representative corrects it.
- Check what calls the pumpA mechanical timer’s dial should be turning and its ON and OFF trippers tight; an automation system or the pump’s own schedule may simply be off. Hayward’s step 3: if you have a timer, make sure it works, and bypass it if necessary.
- Read the display or LEDA variable speed pump with a blinking LED or code is protecting itself; match the code in the fault code table further down this page before anything else.
- Power off, then turn the shaftHayward says to check the motor shaft for free movement. A shaft that will not turn means a jam or seized bearings; one that turns but will not start under power points to the capacitor on single-speed motors.
- Hand it to an electricianTerminal board connections must match the wiring diagram on the motor data plate and the supply voltage (Hayward). Voltage checks at a live motor are work for a licensed electrician.
Extension cords are a common culprit and a hazard. Hayward’s Super Pump manual says low voltage at the motor is frequently caused by undersized wiring or extension cord use, and its above-ground PowerFlo Matrix manual says do not use an extension cord at all (Hayward ISSP1591 Rev H). CPSC data on cords and outlets near pools are in our pool electrocution statistics.
Pool pump timer not working? On an Intermatic T104, the yellow clock dial should spin, the green ON and gold OFF trippers should be screwed tight at the times you want, and the dial must be set to the time of day. Inyo Pools’ install guide wires line power to terminals 1 and 3 and the pump to 2 and 4 (Inyo Pools). A replacement T104M mechanism listed at $79.95 on November 2, 2026.
Variable speed pumps keep their own schedule, so a timer is often the wrong suspect. Pentair’s IntelliFlo3 ships with a Program 1 of 24 hours at 30 GPM, and Jandy’s VS FloPro will not start under automation if DIP switches 3 and 4 set the wrong pump address (Jandy H0661800 Rev C). Controllers and their schedules are compared in our pool automation system guide.
Why is my pool pump humming and not working?
Hum without rotation means the motor has power but cannot turn. Hayward’s chart names an impeller jammed with debris; on single-speed and two-speed motors a failed start or run capacitor does the same. Turn the power off and try the shaft by hand: if it turns freely, suspect the capacitor; if it will not turn, the impeller or bearings are seized.
| Check (power off at the breaker) | Result | What it points to | Source |
|---|---|---|---|
| Turn the motor shaft by hand (rear of motor or through the fan cover) | Turns freely | Failed capacitor on a single-speed or two-speed motor | Inyo Pools, Test a Pool Pump Capacitor (2017) |
| Turn the motor shaft by hand | Will not turn | Impeller jammed with debris, or seized bearings | Hayward Super Pump 1017836 Rev A; Inyo Pools |
| Open the strainer lid, look into the impeller eye | Leaves, pebbles or hair packed in | Jammed impeller; Hayward says have a qualified repair professional open the pump | Hayward Super Pump; Jandy VS FloPro blocked impeller steps |
| Look at the capacitor (single-speed motors only) | Bulged, leaking or burned | Replace with the same MFD rating and equal or higher voltage | Inyo Pools capacitor guide |
| Variable speed pump shows a stalled-motor code | Hayward TriStar XE: 4 flashes | Drive could not start the motor: check impeller, diffuser, shaft seal and motor for binding | Hayward IS3200XE Rev B |
Sources: Hayward Super Pump 1017836 Rev A; Hayward TriStar XE IS3200XE Rev B; Jandy VS FloPro H0661800 Rev C; Inyo Pools, Test a Pool Pump Capacitor (Sept 6, 2017). Download CSV
Capacitors store a charge after the power is off. Inyo Pools’ guide says to discharge one across its terminals with an insulated screwdriver, with eye protection and a cloth over it, because shorted capacitors have been known to explode (Inyo Pools). Replace it with the same MFD rating and equal or higher voltage: a 440 V part can replace a 370 V one. Run capacitors of 30 to 50 MFD at 370 V listed at $22.95 to $39.95 on November 2, 2026.
Variable speed pumps have no start capacitor to blame; their drive reports the problem. Hayward’s TriStar XE flashes 4 times when the drive could not start the motor and points to the impeller, diffuser, shaft seal and motor for binding (Hayward IS3200XE Rev B). Jandy’s blocked-impeller steps start with the breaker off, then lid and basket out, then debris cleared by hand.
Pool pump running but no water flow, or it keeps losing prime?
A pump that runs without moving water has lost prime or is starved on the suction side. Pentair’s SuperFlo VS chart lists a loose impeller, air in the suction line or pump, and clogged plumbing or a dirty filter. Hayward adds full baskets, a closed valve and a suction leak that shows as bubbles at the return fittings in the pool wall.
Work from cheapest to hardest. Fill the strainer pot to the suction port, empty the pump and skimmer baskets, open every valve, and raise the water to the middle of the skimmer opening. Hayward expects a healthy Super Pump to pull 5 to 6 inches of vacuum at the strainer cover with the suction blocked (Hayward 1017836 Rev A). Step-by-step priming limits for 8 pump models are in our guide on how to prime a pool pump.

If the fan at the rear of a Pentair SuperFlo VS spins but no water moves, Pentair says to open the pump and check the impeller is correctly installed (Pentair 356292 Rev A). Jandy’s FloPro chart adds worn impellers and diffusers when there is no air in the system and pressure is still low, and on a new installation it asks for a voltage check within 10% of the data plate.
Why is my pool pump making noise?
The sound tells you the cause. Rattling like gravel is cavitation from a starved suction side or low water; knocking is debris hitting the impeller; a buzz with vibration is a loose mount; a screech or whine is bearings. Hayward ties bearing noise to seal leaks that let chlorinated water wash out the grease, and says replace any leaking seal at once.
| What you hear | Cause in the manuals | Fix | Manual |
|---|---|---|---|
| Gravel or marbles rattling | Cavitation: restricted or undersized suction, low pool water, air leak | Raise water, clean baskets, correct the suction side or throttle returns | Hayward Super Pump |
| Knocking or clatter | Loose stones or debris hitting the impeller | Clean the pump housing | Hayward Super Pump |
| Buzz with vibration | Pump not level or not secured to the pad | Mount level and bolt to the pad; tighten mounting bolts | Hayward Super Pump; Pentair SuperFlo VS |
| Screech or whine | Bearings worn by age, rust, heat or chlorinated water after a seal leak | Replace the leaking seal at once; bearings or motor by a pro | Hayward Super Pump |
| Fan ticking | Debris touching the cooling fan | Clean the fan cover with compressed air | Pentair IntelliFlo3; Pentair SuperFlo VS |
| Loud at high speed only | Motor speed set higher than needed | Reduce speed if possible | Pentair IntelliFlo3 |
Sources: Hayward Super Pump 1017836 Rev A; Pentair IntelliFlo3 P/N 356231 Rev E; Pentair SuperFlo VS P/N 356292 Rev A. Download CSV

Catch the seal before the bearings. A Hayward SPX1600Z2 shaft seal listed at $19.95 and a Pentair IntelliFlo3 seal at $29.95 on November 2, 2026, and Angi puts a seal replacement at $100 to $250 installed against $150 to $350 for bearings (Angi). Hayward notes its pumps have self-lubricating bearings and seals, so no grease is ever added. If the noise comes with water under the motor, our pool pump leaking guide maps six leak points to the maker’s fix and a dated part price.
Why does my pool pump shut off, trip the breaker or show a fault code?
Shutting off on its own is protection, not failure. Hayward’s motors carry an automatic thermal overload that cuts out before the windings burn and restarts once cool, and Pentair’s variable speed drives stop on over-temperature or over-current and retry after 1 minute. A breaker or GFCI that trips is different: it can mean a ground fault, so the pool stays closed until an electrician checks it.
| Pump | Code or alert | What it means | What the manual says to do |
|---|---|---|---|
| Hayward TriStar XE | 1 flash | DC voltage out of range | Check line voltage is within 10% of the rating at the terminal block and the voltage jumper is set right |
| Hayward TriStar XE | 2 flashes | Motor current too high | Check impeller, diffuser, shaft seal and motor for binding |
| Hayward TriStar XE | 3 flashes | Drive (IPM) temperature too high | Clear the motor airflow path; check ambient temperature against the nameplate |
| Hayward TriStar XE | 4 flashes | Pump has stalled | Check impeller, diffuser, shaft seal and motor for binding |
| Hayward TriStar XE | 5 flashes | Internal motor or drive failure | Contact Hayward Technical Service; the motor and drive may need replacing |
| Pentair SuperFlo VS | 21 | Lost link between keypad and motor control | Check the 5-pin connector and cable on the back of the drive |
| Pentair SuperFlo VS | 02 | Power module over-current | If repeated, inspect impeller and shaft seal |
| Pentair SuperFlo VS | 0F | Supply voltage below 99 V | Often clears itself; otherwise check wiring and supply voltage |
| Pentair IntelliFlo3 VSF | Overheat / Drive is Derating | High internal temperature; pump slows itself | Clean the fan guard; resumes when cool |
| Pentair IntelliFlo3 VSF | Over Current | Load rose: debris, part interference, age, voltage | Inspect rotating parts for blockage; restarts after 1 minute |
| Pentair IntelliFlo3 VSF | Over / Under Voltage | Supply voltage outside range | Clears when voltage returns to normal |
| Pentair IntelliFlo3 VSF | Priming Failure | No water in the strainer basket | Fill the pot; adjust priming speed and duration |
| Pentair IntelliFlo3 VSF | Internal Fault | Drive hardware or software error | Disconnect power, reconnect after 1 minute; if it remains, call a qualified pool professional |
| Jandy VS FloPro | Pump not connected | Low-voltage wiring or pump address (DIP switches 3 and 4) wrong | Check the controller wiring and DIP switch settings in section 3.3 |
Sources: Hayward TriStar XE IS3200XE Rev B; Pentair SuperFlo VS P/N 356292 Rev A; Pentair IntelliFlo3 P/N 356231 Rev E; Jandy VS FloPro H0661800 Rev C. Download CSV
Heat shutdowns follow the same causes across makers. Jandy says a pump that gets hot and shuts off periodically needs room for air around the motor and a voltage check within 10% of its data plate (Jandy); Pentair’s IntelliFlo3 flags a blocked cooling fan or high ambient temperature and slows itself first. Hayward’s XE wants 30 seconds with the LED fully off before power is restored.
Trips are the electrical question. CPSC knows of 33 electrocution deaths in US pools and spas from 2002 to 2018 (CPSC), and the 2020 NEC requires GFCI protection when a pool pump motor is replaced (NEC 680.21(D), as printed in the 2020 NEC pool requirements a Connecticut town publishes). Our pool bonding guide covers the bonding an inspector checks; a repeat trip is a licensed electrician’s job, not a reset-and-retry job.
Pool cover pump not working? What the cover pump manual says
Safety and winter covers that hold water need a cover pump, and the Little Giant APCP-1700 is a common one: 1/3 HP, 115 V, switching on at 2.5 in of water and off at 1 in. Its manual traces a pump that will not start to the plug, breaker or a dirty float, and a pump that runs without pumping to an air lock, a blocked or frozen hose, or too much lift.
| Cover pump problem | Probable cause | Fix | Source |
|---|---|---|---|
| Does not turn on | Not plugged in, breaker off, trash on the float, float obstruction | Plug in, reset breaker, remove the float access cover and clean the float | Little Giant APCP-1700 manual 998295 Rev 06 |
| Does not turn on, upside-down test works | Clogged switch | Remove the blue lid and clean buildup | Little Giant APCP-1700 FAQ |
| Runs but does not pump | Air lock, kinked or blocked hose, frozen hose, lift too high | Power off about 1 minute and restart, repeat; clean the vent hole; clear or thaw the hose | Little Giant manual |
| Will not shut off | Float obstruction, air lock, inflow exceeds pump output | Clean the float; clear the air lock; add pump capacity | Little Giant manual |
| Cycles on and off | No check valve on a long discharge so water drains back onto the cover; clogged volute | Install a check valve in the discharge line; clean screen and basket | Little Giant manual |
| Thermal protector trips | Air lock, obstructed impeller, high or low voltage, worn motor | Let it cool, clear the air lock and impeller, check voltage; replace if worn out | Little Giant manual |
| Motor buzzes | Internal motor problem | Replace the pump; the cord and switch are not replaceable parts | Little Giant APCP-1700 FAQ |
Sources: Little Giant APCP-1700 Owner Manual 998295 Rev 06 (03/25); Little Giant APCP-1700 FAQ. Accessed November 2, 2026. Download CSV
Source: Little Giant APCP-1700 Owner's Manual 998295 Rev 06 (03/25), accessed November 2, 2026.. Download chart data (CSV)
Lift and hose size decide the flow. Little Giant rates the APCP-1700 at 1,745 gallons per hour at 1 ft of lift and 490 at 20 ft, with a 26 ft maximum, and recommends a 1 in inside-diameter hose (Little Giant). The manual also says to plug it into a GFCI-protected outlet and not to let it freeze. Solid covers are compared in our pool safety cover guide.

Repair or replace a pool pump that is not working?
Repair when the fault is a part and the pump is young: a capacitor with an hour of labor runs about $98 to $190, a seal $100 to $250 and bearings $150 to $350. Replace when the housing is cracked, the motor is gone on a single-speed pump past DOE’s 7-year mean life, or a variable speed drive shows an internal failure code.
| Fix | Part price (retailer, date) | Installed or repair cost (source) | When it fits |
|---|---|---|---|
| Run capacitor, single-speed motor | $22.95 to $39.95 for 30 to 50 MFD, 370 V (ePoolSupply, Nov 2, 2026) | Technician time at $75 to $150 an hour (Angi, Nov 2025) | Motor hums, shaft turns freely by hand |
| Shaft seal | $19.95 Hayward SPX1600Z2; $29.95 Pentair IntelliFlo3 356210S (ePoolSupply, Nov 2, 2026) | $100 to $250 (Angi, Nov 2025) | Water dripping under the motor; do it before bearings fail |
| Bearings | Varies by motor | $150 to $350 (Angi, Nov 2025) | Screech or whine, seal leak caught late |
| Motor replacement | $667.99 to $895.95 for a 1.65 HP Century VGreen 165 variable speed motor (Oct 19, 2026) | $350 to $700 (Angi); $200 to $800, $500 average (HomeAdvisor, June 2026) | Housing and impeller sound; motors of 1.15 to 5 THP made since Sept 29, 2025 must be variable speed |
| Variable speed motor plus labor | $667.99 to $895.95 | $767.99 to $1,295.95 (part + $100 to $400 labor) | Old single-speed motor failed |
| Whole variable speed pump | $1,739 median list, 1.5 to 1.65 THP (2026) | $1,839 to $2,139 before any permit | Cracked housing, pump past DOE's 7-year mean life |
Sources: Angi (Nov 25, 2025); HomeAdvisor (June 19, 2026); ePoolSupply (Nov 2, 2026); INYOPools (Oct 19, 2026); 10 CFR 431.485; DOE, 82 FR 5650; PC&S pool pump replacement cost guide. Download CSV
Source: Angi (Nov 25, 2025); ePoolSupply (Nov 2, 2026); INYOPools and The Pool Supply Warehouse (Oct 19, 2026); PC&S pool pump replacement cost guide.. Download chart data (CSV)
| Line | Item | Amount | Source |
|---|---|---|---|
| 1 | 9-year-old single-speed pump hums, shaft turns: capacitor part | $22.95 to $39.95 | ePoolSupply, Nov 2, 2026 |
| 2 | One hour of technician time to test and fit it | $75 to $150 | Angi (Nov 2025) |
| 3 | Capacitor repair total (1 + 2) | $97.95 to $189.95 | PC&S arithmetic |
| 4 | New variable speed pump installed instead | $1,839 to $2,139 | PC&S pool pump replacement cost guide |
| 5 | Yearly electricity saving, single-speed to variable speed, median state (North Carolina) | $487 | PC&S cost to run a pool pump report (EIA July 2026, DOE seasons) |
| 6 | Extra cost of replacing now (4 minus 3) | $1,649.05 to $2,041.05 | PC&S arithmetic |
| 7 | Years for the saving to cover line 6 (6 / 5) | 3.4 to 4.2 years | PC&S arithmetic |
| 8 | Pump age against DOE's 7-year mean life | 2 years past | DOE, 82 FR 5650 |
Sources: ePoolSupply; Angi; PC&S cost to run a pool pump report (EIA July 2026, DOE seasons); DOE, 82 FR 5650. PC&S arithmetic. Download CSV
In the worked example the capacitor is the cheap fix, but the pump is 2 years past DOE’s mean life, so the next fault is near. Replacing now costs $1,649.05 to $2,041.05 more and pays back in 3.4 to 4.2 years in the median state, faster where electricity costs more. Line-item installed prices are in our pool pump replacement cost guide, and speed settings in our variable speed pool pump guide.
| If your situation is | Do this | Number behind it |
|---|---|---|
| Breaker or GFCI trips, or anyone feels a tingle in the water | Keep power off and people out of the pool; call a licensed electrician | CPSC: 33 electrocution deaths in US pools and spas, 2002 to 2018 |
| Pump is silent and the breaker is on | Check the timer, automation schedule and relay before the motor | Hayward lists switches, relays and timers ahead of the motor |
| Hums, shaft turns by hand, single-speed motor under 7 years old | Replace the capacitor | $22.95 to $39.95 part; $97.95 to $189.95 with an hour of labor |
| Hums, shaft will not turn | Clear the impeller or replace bearings, by a pro | Bearings $150 to $350 (Angi) |
| Leak under the motor, no noise yet | Replace the shaft seal now | Seal $100 to $250 installed (Angi); part $19.95 to $29.95 |
| Motor failed, housing sound, pump under 8 years | Fit a variable speed replacement motor | $767.99 to $1,295.95 with labor; single-speed motors of 1.15 to 5 THP made since Sept 29, 2025 are not allowed |
| Single-speed pump older than 7 years with any motor fault | Price a whole variable speed pump | $1,839 to $2,139 installed; $487 a year saved in the median state |
| Variable speed pump shows the same fault code after a power cycle | Call the maker's technical service or a pool pro; ask about drive warranty | Hayward TriStar XE 5 flashes = internal motor or drive failure |
Sources: CPSC; Hayward 1017836 Rev A; Hayward IS3200XE Rev B; Angi; 10 CFR 431.485; DOE, 82 FR 5650; ePoolSupply and INYOPools listings. Download CSV
How we compiled this
On November 2, 2026 we read the troubleshooting sections of 9 manuals: Hayward Super Pump, TriStar XE and PowerFlo Matrix; Pentair IntelliFlo3, SuperFlo VS and SuperFlo; Jandy FloPro and VS FloPro; and the Little Giant APCP-1700, plus Little Giant’s FAQ, an Inyo Pools capacitor guide and CPSC’s pool shock page. Part prices are ePoolSupply listings from that day; repair costs come from Angi and HomeAdvisor. We did not test any pump, and forum posts were excluded.
Frequently Asked Questions
Why is my pool pump not working?
Usually power, a jam or heat. Hayward’s Super Pump manual checks wiring, tripped breakers, GFCIs, fuses and the timer first, then whether the shaft turns freely. A humming motor points to a jammed impeller or failed capacitor, and a pump that runs then stops is often tripping its automatic thermal overload from low voltage or poor airflow.
Why is my pool pump humming and not working?
The motor has power but cannot turn. Hayward lists an impeller jammed with debris; on single-speed motors a failed capacitor causes the same hum. With the breaker off, turn the shaft by hand: if it spins freely, suspect the capacitor ($22.95 to $39.95 for a 30 to 50 MFD part); if it is stuck, the impeller or bearings need a pro.
How do I reset my pool pump?
Turn it off at the breaker, wait, then restore power. Hayward’s TriStar XE needs 30 seconds with the LED fully off; Pentair’s IntelliFlo3 manual says disconnect power and reconnect after 1 minute for an internal fault. If a breaker or GFCI trips again after one reset, leave it off and call a licensed electrician.
Why does my pool pump keep shutting off?
Most pumps protect themselves from heat. Hayward’s motors carry an automatic thermal overload that restarts once cool, and Jandy says a pump that gets hot and shuts off needs air space around the motor and voltage within 10% of its data plate. Pentair’s variable speed drives stop on over-temperature or over-current and retry after 1 minute.
How do I know if my pool pump motor is bad?
Signs in the manuals: a screech or whine from bearings, a hum with a shaft that will not turn, a variable speed drive that shows an internal failure code (5 flashes on a Hayward TriStar XE) or repeated over-current faults. A motor replacement runs $350 to $700 (Angi), and a variable speed motor part $667.99 to $895.95.
Why is my pool cover pump not working?
On a Little Giant APCP-1700, check the plug and breaker, then clean the float, which switches the pump on at 2.5 in of water and off at 1 in. If it runs without pumping, clear an air lock by switching off for about 1 minute and restarting, and check the hose for kinks or ice. A buzzing motor means replacement.
Sources
- Hayward. Super Pump Series Owner's Manual, 1017836 Rev A. Accessed 2026-11-02.
- Hayward. TriStar XE Pump Series Owner's Manual, IS3200XE Rev B. Accessed 2026-11-02.
- Hayward. PowerFlo Matrix Pump Owner's Manual, ISSP1591 Rev H. Accessed 2026-11-02.
- Pentair. IntelliFlo3 VSF / IntelliPro3 VSF Installation and Maintenance Guide, P/N 356231 Rev E. Accessed 2026-11-02.
- Pentair. SuperFlo VST, SuperFlo VS and SuperMax VS Installation and User's Guide, P/N 356292 Rev A. Accessed 2026-11-02.
- Pentair. SuperFlo High Performance Pump Installation and User's Guide, P/N 356968 Rev C. Accessed 2026-11-02.
- Zodiac Pool Systems (Jandy). FloPro (FHP) Series Pumps Installation and Operation Manual, H0315300 Rev U. Accessed 2026-11-02.
- Zodiac Pool Systems (Jandy). VS FloPro Variable-Speed Pumps Installation and Operation Manual, H0661800 Rev C (dealer-hosted copy). Accessed 2026-11-02.
- Little Giant (Franklin Electric). APCP-1700 Automatic Pool Cover Pump Owner's Manual, 998295 Rev 06 (03/25). Accessed 2026-11-02.
- Little Giant. APCP-1700 technical support FAQ. Accessed 2026-11-02.
- Inyo Pools. How to Test a Pool Pump Capacitor (Sept 6, 2017). Accessed 2026-11-02.
- Inyo Pools. How to Install an Intermatic T104 Timer. Accessed 2026-11-02.
- Angi. How Much Does It Cost to Repair a Pool Pump? (Nov 25, 2025, Wayback copy). Accessed 2026-11-02.
- HomeAdvisor. Install or replace a pool pump cost (June 19, 2026). Accessed 2026-11-02.
- ePoolSupply. Part listings: shaft seals, capacitors, T104M time switch. Accessed 2026-11-02.
- INYOPools. Century VGreen 165 ECM16SQU listing (Oct 19, 2026). Accessed 2026-11-02.
- eCFR. 10 CFR 431.485, pool pump motor standards. Accessed 2026-11-02.
- U.S. Department of Energy. Energy Conservation Standards for Dedicated-Purpose Pool Pumps, 82 FR 5650. Accessed 2026-11-02.
- U.S. Energy Information Administration. Electric Power Monthly Table 5.6.A (July 2026). Accessed 2026-11-02.
- Town of Woodbury, CT. 2020 National Electrical Code in-ground pool requirements (NEC 680.21(D)). Accessed 2026-11-02.
- U.S. Consumer Product Safety Commission. Don't Swim with Shocks: Electrical Safety In and Around Pools. Accessed 2026-11-02.
Related pages
Get Quotes From Licensed Local Pool Pros
Tell us what you need and your ZIP code. We match you with pool companies that cover your area.