Skip to content
Backyard pool at dusk with the underwater light switched off
Pool care: equipment

Pool Light Not Working? Troubleshoot From Breaker and GFCI to Bulb and Niche, Safely

Pool light not working? Check the switch, timer and breaker, reset a tripped GFCI once, then resync color lights and check the water level; a GFCI that trips again means a fault for a licensed electrician.

Free Pool Quote Match

Tell us about your pool project. We match you with licensed local pros who cover your area.

Step 1 of 3: Your project

Free for homeownersNo obligationAbout 60 seconds

  • ✓Power off before hands onBulb and gasket work happens on the deck with the breaker off (2024 IRC E4206.5.1).
  • ✓A tripping GFCI is a warningIt cuts power at as little as 0.006 A of leakage (CPSC).
  • ✓Out of sync is not brokenHayward resyncs with an 11 to 13 second off period.
Quick answer
Most dead pool lights are a switch, timer, tripped breaker or GFCI. Reset the GFCI once; if it trips again, stop and call a licensed electrician. Color LEDs that act up need the maker’s resync, Hayward’s 11 to 13 seconds off. Repairs run $65 to $150 per light (Angi, July 2026); replacement $500 to $1,700 (HomeGuide, 2025).
0.006 A
GFCI trip point
Source: CPSC
$65 to $150
Repair per light
NEC 680.23(A)(3)
Code section

Key takeaways

  • Start with power you can see: switch, timer, automation schedule, breaker and GFCI. Pentair’s only troubleshooting line for a dark IntelliBrite 5g is to check the ground fault wiring and reset if necessary (Pentair guide, P/N 619827 Rev C).
  • A GFCI cuts power when as little as 0.006 A leaks to ground, and CPSC says to test every GFCI at least once a month and after a power failure (CPSC fact sheet). One that trips again after a reset is reporting a fault.
  • Under NEC 680.23(A)(3), mirrored in 2024 IRC E4206.4, any underwater light above the 15 V low-voltage contact limit must be on a GFCI to protect people relamping or servicing it. Never bypass it.
  • Hayward color lights that fall out of step resync with a timed 11 to 13 second off period, and flashing or dim lights get a 2 minute power-down, per Hayward TSG-UCL100e.
  • CPSC lists underwater lights that flicker, or are on when they should be off, among the warning signs of current in the water and knows of 33 pool and spa electrocution deaths since 2002 (CPSC).

Why is my pool light not working?

Eight faults cover nearly every dead or misbehaving pool light: no power from the switch, timer or breaker; a tripped GFCI; a failed 12 V transformer; thermal shutdown from low water; color lights out of sync; flicker from voltage drop; water inside the lens; and a burned-out incandescent lamp. The symptom table maps each one to a safe first check and the right person to fix it.

Pool light not working: symptom, cause, safe first check and who fixes it
SymptomMost likely causeSafe first checkWho fixes itSource
Light dark, everything else on the circuit dark tooTripped breaker or GFCI, or the timer or automation relay is not calling for the lightCheck the switch, timer and automation schedule; reset the GFCI onceOwner; electrician if the GFCI trips againPentair IntelliBrite 5g guide; Hayward TSG-UCL100e
GFCI trips as soon as the light is switched onGround fault: water in the fixture or cord, or damaged wiringLeave it off and keep people out of the waterLicensed electrician or qualified pool proCPSC GFCI fact sheet; 2024 IRC E4206.4 (NEC 680.23(A)(3))
Light dark, GFCI and breaker fine, 12 V systemFailed transformer or loose low-voltage junctionConfirm the transformer's switch or relay is onPool pro with a meter: 120 V in, 12 to 14 V outHayward TSG-UCL100e, pages 18 to 20
Light goes off after a few minutes, then back onThermal protection: the fixture is not fully under waterCheck the water level against the lightOwner: top up the poolPentair IntelliBrite 5g guide (10 minute cool-down)
Color lights show different colorsLights out of sync after a power outage, brownout or rapid togglingRun the maker's resync sequenceOwnerHayward TSG-UCL100e, pages 7 and 21 to 23
Flickering or dimVoltage drop, a poor connection or a failing light; flicker can also signal current in the waterGet swimmers out; power off 2 minutes, then retestElectrician if it persistsHayward TSG-UCL100e, pages 24 to 26; CPSC
Fog or water droplets inside the lensFailed lens gasket or cord sealSwitch off at the breaker; do not use the lightPool pro: new gasket or fixturePentair guide (new lens gasket P/N 79101600); 2024 IRC E4206.5 (NEC 680.23(B)(4))
Incandescent light dark, nothing trippedBurned-out lamp: about 2,000 hours average life for a 500 W R40 pool lampBreaker off, then lift the fixture onto the deckOwner if comfortable; pool pro otherwiseHalco 104042 listing (ePoolSupply, Nov 2026)

Sources: Pentair IntelliBrite 5g guide (P/N 619827 Rev C); Hayward TSG-UCL100e (2017); CPSC GFCI fact sheet; CPSC Don’t Swim With Shocks; 2024 IRC Chapter 42; ePoolSupply Halco listing. Accessed November 9, 2026. Download CSV

Two causes are easy to miss. Pentair says an IntelliBrite left out of the water and powered on for more than 10 minutes switches itself off for a 10 minute cool-down, so a light near a low waterline can cycle on and off. Hayward says switched color lights fall out of sync after power outages, brownouts, repeated toggling, voltage drop or an overloaded transformer; that looks like a fault but is fixed with a resync.

How do you troubleshoot a pool light, step by step?

Work from the outside in, and stop where the next step needs tools on a live circuit. Check the switch and schedule, then the breaker, then reset the GFCI once, then resync or power-cycle color lights, then check the water level and the lens. Anything inside the junction box, transformer or a 120 V circuit belongs to a licensed electrician or qualified pool pro.

Pool light troubleshooting flowchart built by PC&S from the Pentair IntelliBrite 5g guide, Hayward TSG-UCL100e, CPSC and 2024 IRC E4206 (NEC 680.23), November 2026. The numbered steps and the decision table hold the same logic as text.
Pool light troubleshooting flowchart built by PC&S from the Pentair IntelliBrite 5g guide, Hayward TSG-UCL100e, CPSC and 2024 IRC E4206 (NEC 680.23), November 2026. The numbered steps and the decision table hold the same logic as text.
  1. Clear the water firstIf anyone feels tingling, or the light flickers or is on when it should be off, get everyone out without the metal ladder and cut power at the breaker (CPSC).
  2. Check the switch, timer and automationConfirm the wall switch is on, the timer is not in its off window, and the automation relay or app is calling for the light (Hayward TSG-UCL100e, page 19).
  3. Check the breakerA tripped breaker sits in the middle or off position; switch it fully off, then on.
  4. Reset the GFCI oncePress reset on the GFCI receptacle or breaker that feeds the light. If it trips again with the light on, stop here: leave it off and call an electrician.
  5. Power-cycle or resync color lightsPentair: off more than 5 seconds restores the last saved show. Hayward: on at least 60 seconds, off 11 to 13 seconds, back on; then off 2 minutes to lock.
  6. Check the water levelThe top of the lens sits at least 18 in below normal water level (2024 IRC E4206.4.2); a low pool can trigger thermal shutdown on some LEDs.
  7. Look at the lens from the deckFog, droplets or a dark patch inside means water got past the gasket or cord seal: breaker off, do not use the light.
  8. Lamp or fixture work, breaker offWith the breaker off and the switch tested dark, a wet-niche light lifts onto the deck without draining; the relamp steps are in our pool lighting guide.

The full relamp and fixture-swap procedure, with Pentair’s 12 manual steps and the 4 ft of coiled cord, is in our pool lighting guide, so this page stops at diagnosis. Lights wired through a controller often fail at the relay or schedule, which our pool automation system guide explains.

Why does my pool light keep tripping the GFCI?

Because current is leaking to ground somewhere on the light circuit, most often water inside the fixture or cord, or damaged wiring in the conduit or junction box. A GFCI trips at as little as 0.006 A of difference between outgoing and returning current, according to CPSC. Reset it once; a second trip means the fault is still there, and it needs an electrician.

The code assumes water can reach the fixture. 2024 IRC E4206.5 (NEC 680.23(B)(4)) requires the cord ends inside a wet-niche light to be potted so water cannot enter through the cord, and E4206.4 puts a GFCI on every light above 15 V precisely to protect the person relamping it. A light that trips its GFCI after years of service usually has a failed lens gasket, which is why Pentair says to always fit a new gasket (P/N 79101600) whenever an IntelliBrite is opened.

Old GFCIs fail too. CPSC says blackouts and power disturbances can damage a GFCI, so test it monthly: press test, the protected device should go dark; press reset, it should come back. If it will not reset with the light disconnected by an electrician, the GFCI itself is bad. Bonding faults, a separate safety system, are covered in our pool bonding guide.

How do I reset my pool light?

By timing the power. Switched color lights reset and resync through the wall switch: Pentair IntelliBrite 5g returns to its last saved show after more than 5 seconds off, and Hayward Universal ColorLogic resyncs with an off period of exactly 11 to 13 seconds, then 2 minutes off to lock it in. A tripped GFCI resets with its button, once.

How to reset or resync pool lights, by maker and control
LightHow to reset or resyncSource
Pentair IntelliBrite 5g (switched)Power is off more than 5 seconds: the light returns to the last saved show or color. Switch off and on 1 to 12 times to pick a show or color; 13 times holds, 14 recallsPentair IntelliBrite 5g guide, P/N 619827 Rev C, pages 2 to 5
Hayward Universal ColorLogic and CrystaLogic (switched)Light on at least 60 seconds; off for 11 to 13 seconds, then straight back on; repeat until all lights match; then off at least 2 minutesHayward TSG-UCL100e, page 7
Hayward lights on an OmniLogicTap the light on the dashboard, pick the body of water, tap the resync iconHayward TSG-UCL100e, page 8
Hayward ColorLogic Light ControllerLights on, wait 2 minutes, hold the resync button at least 3 secondsHayward TSG-UCL100e, page 9
Any light, flashing or dimPower down at least 2 minutes at the breaker or controller, then retestHayward TSG-UCL100e, page 25
GFCI receptacle or breakerPress reset once. If it trips again, stop and call an electricianCPSC GFCI fact sheet (Pub. 099)

Sources: Pentair IntelliBrite 5g guide, P/N 619827 Rev C; Hayward TSG-UCL100e (2017); CPSC Pub. 099. Accessed November 9, 2026. Download CSV

Hayward's manual resync sequence for switched Universal ColorLogic lights: on at least 60 seconds, off 11 to 13 seconds, back on, then off at least 2 minutes. From Hayward TSG-UCL100e, page 7 (2017), accessed November 9, 2026. Red box added by PC&S.
Hayward’s manual resync sequence for switched Universal ColorLogic lights: on at least 60 seconds, off 11 to 13 seconds, back on, then off at least 2 minutes. From Hayward TSG-UCL100e, page 7 (2017), accessed November 9, 2026. Red box added by PC&S.

Why is my pool light flickering or dim?

Treat flicker as a safety signal first: CPSC lists flickering underwater lights among the signs of electricity in the water, so get swimmers out. Then the usual causes are voltage drop, a poor connection or a failing light. Hayward’s guide says its LEDs flash when they get too little power and need 12 to 14 V AC at the junction point.

Hayward’s sequence for a flashing or dim switched light is a 2 minute power-down at the breaker or controller, then a retest; if it still flashes, a technician checks for 12 to 14 V at the junction box and 120 V in and 14 V out at the transformer (TSG-UCL100e, pages 24 to 26). Long cords and several lights on one 300 W transformer add voltage drop; Pentair recommends no more than 3 pool lights and 1 spa light on one 300 W transformer and 100 ft of total cable.

Of 35 sampled emergency room cases of pool and spa electrical injury from 2015 to 2025, a pool light was the source in 2, per our pool electrocution statistics; cords, plugs and outlets caused more. Rare is not zero, which is why the flicker check comes before the meter.

What does NEC 680 say when you fix a pool light?

Article 680 of the National Electrical Code, mirrored in Chapter 42 of the 2024 International Residential Code, sets the rules a repair must keep: GFCI on lights above 15 V (680.23(A)(3)), a Class A GFCI (680.5), sealed cord ends (680.23(B)(4)), deck servicing without entering the water (680.23(B)(6)), and a junction box 4 ft from the pool (680.24(A)(2)).

NEC 680 and 2024 IRC rules that matter when a pool light fails
Rule that matters when a light fails2024 IRC2023 NECWhat it means for troubleshooting
GFCI on lights above the low-voltage contact limit, to protect people lamping, relamping or servicingE4206.4680.23(A)(3)A 120 V light that trips its GFCI is doing its job; find the fault, do not bypass it
Low-voltage contact limit: 15 V RMS sinusoidal ACChapter 35 definition680.212 V lights on a listed transformer need no GFCI on the light side
Class A GFCI where the chapter requires ground-fault protectionE4206.2680.5(A) and (B)Replace a failed GFCI with a listed Class A device
Cord ends potted inside the fixture to keep water outE4206.5680.23(B)(4)Water in the lens or cord means the seal failed; the fixture needs service
Wet-niche light lifts out to the deck without anyone entering the waterE4206.5.1680.23(B)(6)Bulb and gasket work happens on the deck with the breaker off
Junction box 4 ft from the inside wall, 4 in above deck or 8 in above max water levelE4206.9.1680.24(A)(2)The box you may see on the deck; opening it is electrician work
Strain relief where the light cord ends in the boxE4206.9.5680.24(E)A cord pulled loose at the box can cut power to the light
Supply circuit no more than 150 V between conductorsE4206.4.1680.23(A)(4)Pool lights run on 120 V or 12 V systems

Sources: 2024 IRC Chapter 42 (bracketed 2023 NEC sections), via UpCodes; 2024 IRC Chapter 35 definitions. Accessed November 8 and 9, 2026. Download CSV

Older pools are not forced to upgrade until work is done: CPSC notes the NEC typically applies to new construction or major renovations, and its GFCI rule for underwater pool lighting dates to 1968. A new light circuit or fixture swap may need a permit; unincorporated Miami-Dade charges $148.68 for a residential pool electrical permit that covers lights, and our pool permits guide explains when one applies. Spa lights and the GFCI rules for hot tubs, 680.43 and 680.44, are covered in our hot tub wiring guide.

How much does it cost to fix a pool light, and how long do they last?

A repair runs $65 to $150 per light and a full replacement $500 to $1,700 with fixture and labor, according to Angi (July 2026) and HomeGuide (2025). A 500 W incandescent R40 pool lamp averages 2,000 hours, about 1.4 years at 4 hours a night, and costs $24.69 (ePoolSupply, November 2026). Hayward says its LEDs last 10 times longer.

A working light at night: a 500 W incandescent pool lamp averages about 2,000 hours (Halco 104042 listing, November 2026), roughly 1.4 years at 4 hours a night.
A working light at night: a 500 W incandescent pool lamp averages about 2,000 hours (Halco 104042 listing, November 2026), roughly 1.4 years at 4 hours a night.
Pool light repair and replacement costs, with source and date
ItemCostSource and date
Repair per light (diagnose, reseal, reconnect)$65 to $150Angi, updated July 9, 2026
Pool repair labor$45 to $65 per hourAngi, 2026
500 W incandescent R40 lamp, Halco 104042$24.69ePoolSupply, November 9, 2026
Bulbs alone$20 to $100Angi, 2026
LED fixture alone (12 models listed)$374.95 to $1,469.00ePoolSupply and Inyo Pools, November 1, 2026
Replace a light, fixture and labor$500 to $1,700HomeGuide, 2025
Electrical permit, residential pool or spa incl. lights (unincorporated Miami-Dade)$148.68Miami-Dade Implementing Order 4-63

Sources: Angi (Wayback, July 2026); HomeGuide 2025; ePoolSupply, Nov 9, 2026; ePoolSupply fixture listings, Nov 1, 2026; Miami-Dade IO 4-63. Download CSV

Pool light repair and replacement cost ranges, US (dollars)Published ranges, 2025 to 2026
Pool light repair and replacement cost ranges, US (dollars)Range chart: repair $65 to $150 per light, bulb alone $20 to $100, LED fixture alone $374.95 to $1,469, replacement with labor $500 to $1,700.$0$500$1,000$1,500$2,000Repair per light (Angi): $65 to $150Repair per light (Angi)Bulb alone (Angi): $20 to $100Bulb alone (Angi)LED fixture alone (ePoolSupply, Inyo): $375 to $1,469LED fixture alone (ePoolSupply, Inyo)Replace, fixture and labor (HomeGuide): $500 to $1,700Replace, fixture and labor (HomeGuide)

Source: Angi (updated July 9, 2026); ePoolSupply and Inyo Pools listings (Nov 1, 2026); HomeGuide (2025).. Download chart data (CSV)

Worked arithmetic: lamp life, repair vs replace
QuestionInput or formulaResult
How long does a 500 W lamp last at 4 hours a night?2,000 hours average life / 4 hours per night500 nights, about 1.4 years
At 1 hour a night?2,000 / 12,000 nights, about 5.5 years
Lamp vs new LED fixture$24.69 lamp vs $824.95 Pentair IntelliBrite 5g Color, 50 ft (ePoolSupply)The lamp costs about 3% of the fixture
Repair vs replace$65 to $150 repair (Angi) vs $500 to $1,700 replacement (HomeGuide)Repair first unless the fixture or niche is damaged
Hayward LED warranty window3 years parts, 1 year labor (CrystaLogic 320 page)Check the receipt before paying for a repair

Sources: Halco 104042 listing; ePoolSupply; Angi; HomeGuide; Hayward CrystaLogic 320 page. PC&S arithmetic, November 2026. Download CSV

Fixture specs, LED running costs and the 6.6 year payback of swapping a 500 W lamp for a 26 W LED are worked out in our pool lighting guide. Other jobs often bundled with a light repair are priced in our pool repair guide.

Which pool light fixes are DIY, and when do you call an electrician?

DIY stops at switches, schedules, a single GFCI reset, resync sequences, the water level and looking at the lens. Call a licensed electrician when a GFCI trips again, anyone feels tingling, the lens holds water, a 12 V system shows no output, the cord will not pull, or the junction box is corroded. A bulb swap with the breaker off is DIY only if you are comfortable doing it.

Pool light not working: key numbers with the source of each
NumberWhat it meansSource
0.006 ALeakage current at which a GFCI cuts powerCPSC GFCI fact sheet
Once a monthHow often to test every GFCI, plus after a power failureCPSC GFCI fact sheet
15 VLow-voltage contact limit (AC RMS); above it, an underwater light needs a GFCI2024 IRC Ch. 35; NEC 680.2, 680.23(A)(3)
11 to 13 secondsTimed off period to resync Hayward switched color lightsHayward TSG-UCL100e
10 minutesPentair IntelliBrite cool-down if run out of water more than 10 minutesPentair guide
12 to 14 V ACVoltage a Hayward low-voltage light needs at the junction pointHayward TSG-UCL100e
2,000 hoursAverage life of a 500 W R40 pool lampHalco 104042 listing, Nov 2026
33Pool and spa electrocution deaths known to CPSC since 2002CPSC

Sources: CPSC GFCI fact sheet; 2024 IRC Ch. 35; Hayward TSG-UCL100e; Pentair guide; ePoolSupply; CPSC. Download CSV

Pool light decision table: if your situation is X, do Y
If your situation isDo thisWhy (source)
Anyone feels tingling, or the light flickers or is on when it should be offGet everyone out without the metal ladder, cut power at the breaker, call an electricianCPSC lists these as warning signs of current in the water
Light dark, switch or timer offTurn it on or fix the schedule; check the automation relay is calling for the lightHayward: make sure the lights are being called for
GFCI tripped onceReset it once and test the lightCPSC: test and reset procedure
GFCI trips againLeave it off and book a licensed electrician; do not swap in a non-GFCI device2024 IRC E4206.4 (NEC 680.23(A)(3)) requires the GFCI
Color lights out of stepRun the maker's resync: Hayward 11 to 13 s off; Pentair off more than 5 sHayward TSG-UCL100e; Pentair guide
Light cycles off and on, water lowTop up above the lightPentair 10 minute thermal cool-down
Fog or water in the lensBreaker off; new gasket or fixture by a proPentair: always fit a new lens gasket when opened
Incandescent dark, nothing trippedBreaker off, lift fixture to the deck, replace the lamp and gasket, or hire a pool pro2024 IRC E4206.5.1; Pentair relamp steps
12 V light dark, GFCI finePool pro checks 120 V in and 12 to 14 V out at the transformerHayward TSG-UCL100e
Cord will not pull, niche cracked or junction box corrodedLicensed electrician; ask whether a permit is neededMiami-Dade charges $148.68 for a pool electrical permit

Sources: Pentair IntelliBrite 5g guide (P/N 619827 Rev C); Hayward TSG-UCL100e (2017); CPSC GFCI fact sheet; CPSC Don’t Swim With Shocks; 2024 IRC Chapter 42; ePoolSupply Halco listing. Accessed November 9, 2026. Download CSV

How we compiled this

In November 2026 we read Pentair’s IntelliBrite 5g guide (P/N 619827 Rev C), Hayward’s 43-page Universal ColorLogic troubleshooting guide (TSG-UCL100e), Chapter 42 of the 2024 IRC with its bracketed 2023 NEC sections, CPSC’s GFCI fact sheet and pool shock page, a retailer lamp listing and the six readable top-ranking pages: 8 primary documents, plus cost figures reused from our pool lighting guide. We did not test any light; forum posts were read for question wording only.

Frequently Asked Questions

How do I reset my pool light?

Time the power off. A Pentair IntelliBrite 5g returns to its last saved show after more than 5 seconds off. A Hayward switched color light resyncs when you leave it on 60 seconds, switch it off for 11 to 13 seconds and straight back on, then off for 2 minutes. If a GFCI tripped, press reset once; a second trip needs an electrician.

What causes pool lights to stop working?

Usually power, not the light: a switch, timer or automation schedule, a tripped breaker, or a GFCI that tripped on a ground fault such as water in the fixture. Then come color lights out of sync, a failed 12 V transformer, thermal shutdown from low water and burned-out lamps; a 500 W R40 pool lamp averages 2,000 hours (Halco listing, 2026).

How much does a pool light cost to fix?

$65 to $150 per light for a repair such as resealing or reconnecting, according to Angi (updated July 2026), and $500 to $1,700 per light to replace the fixture with labor, according to HomeGuide (2025). A 500 W incandescent lamp alone was $24.69 at ePoolSupply in November 2026, and LED fixtures listed at $374.95 to $1,469.00.

What is the average lifespan of a pool light?

A 500 W incandescent R40 pool lamp averages 2,000 hours, per the Halco 104042 listing (2026): about 1.4 years at 4 hours a night or 5.5 years at 1 hour. Hayward says its CrystaLogic LEDs last 10 times longer than incandescent bulbs, and covers them for 3 years on parts and 1 year on labor.

Why does my pool light keep tripping the GFCI?

A ground fault: current leaking to ground, often through water inside the fixture or cord, or damaged wiring. A GFCI trips at as little as 0.006 A (CPSC), and NEC 680.23(A)(3) requires one on any underwater light above 15 V. Reset it once; if it trips again, leave it off and call a licensed electrician.

Is a flickering pool light dangerous?

It can be. CPSC lists underwater lights that flicker, or are on when they should be off, among the warning signs of electricity in the water. Get everyone out without using a metal ladder and cut power at the breaker. Once the pool is clear, Hayward’s guide traces most flicker to voltage drop, poor connections or a failing light.

Sources

  1. International Code Council via UpCodes. 2024 International Residential Code, Chapter 42 Swimming Pools (bracketed 2023 NEC sections). Accessed 2026-11-08.
  2. International Code Council via UpCodes. 2024 International Residential Code, Chapter 35 definitions (low-voltage contact limit). Accessed 2026-11-01.
  3. Pentair. IntelliBrite 5g Pool LED Light Installation and User's Guide, P/N 619827 Rev C. Accessed 2026-11-09.
  4. Hayward. Universal ColorLogic & CrystaLogic Troubleshooting Guide Residential, TSG-UCL100e (2017). Accessed 2026-11-09.
  5. CPSC. GFCI Fact Sheet, Pub. 099. Accessed 2026-11-09.
  6. CPSC. Don't Swim With Shocks: Electrical Safety In and Around Pools, Spas and Hot Tubs. Accessed 2026-11-09.
  7. ePoolSupply. Halco 104042 Incandescent R40 Lamp 500 W listing. Accessed 2026-11-09.
  8. Hayward. CrystaLogic 320 product page. Accessed 2026-11-01.
  9. Angi. How Much Do Swimming Pool Repairs Cost? (updated July 9, 2026), Wayback copy. Accessed 2026-10-08.
  10. HomeGuide. How Much Does It Cost to Repair a Pool? (2025). Accessed 2026-10-08.
  11. ePoolSupply. Pool light listings. Accessed 2026-11-01.
  12. Miami-Dade County. Implementing Order 4-63, fee schedule. Accessed 2026-10-07.
Free for homeowners

Get Quotes From Licensed Local Pool Pros

Tell us what you need and your ZIP code. We match you with pool companies that cover your area.