Rule,Number,NEC section (2023),Source Minimum bonding conductor,8 AWG solid copper (2026 NEC adds 40% copper-clad steel),680.26(B),2024 IRC E4204.2; JADE Learning Perimeter surface reach,3 ft horizontally from the inside pool wall,680.26(B)(2),2024 IRC E4204.2 Perimeter surface height band,3 ft above to 2 ft below max water level (2023 with TIA 23-9); 3 ft below in 2026,680.26(B)(2),JADE Learning; Hamilton & Associates "Tie points, conductive shell","4 or more, uniformly spaced",680.26(B)(2),2024 IRC E4204.2 Unpaved single conductor,"18 to 24 in from inside wall, 4 to 6 in below finished grade",680.26(B)(2)(b),2024 IRC E4204.2 Copper grid in or under shell,"12 x 12 in, 4 in tolerance, within 6 in of outer shell",680.26(B)(1)(b),2024 IRC E4204.2 Fixed metal reach,"5 ft horizontally, 12 ft vertically above max water level",680.26(B)(7),2024 IRC E4204.2 Pool water bond,"9 sq in (5,800 sq mm) of conductive surface",680.26(C),2024 IRC E4204.3 Wall that limits the perimeter,Permanent wall or building 5 ft tall or more,680.26(B)(2),2024 IRC E4204.2 Small metal parts exempt,4 in or less in any dimension and 1 in or less into the structure,680.26(B)(5),2024 IRC E4204.2